Delem
V0606, 2.11
•
Parameter explanation
Optimalisation Degree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OD=
Range 1-5.
The number of alternative sequences to be computed for each bending must be entered
here.
The higher this number the more alternatives are to be examined by the processor, so the
longer the computing time will be.
Front Extend Ratio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FR=
Range 0.0 - 1.0.
This is the ratio of the minimum allowable length of your product which extends in front
of the press to the total blank length of the product. You must have a minimum length of
your product in front of the press to be able to handle the product.
Front Extend Ratio Accept . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FA=
- In case programmed 0 (comply if possible):
This means that when possible the computer tries to comply to the front extend ratio and
only when this will result in no solutions to be found it will accept that the length in front
is smaller than the specified ratio.
- In case programmed 1 (comply always):
The computer will always comply to the front extend ratio. This may result in no solu-
tions to be found.
Press the key to select the required setting.
Summary of Contents for DA-65W
Page 1: ...Delem Manual version V0606 DA 65W Reference Manual Operation of Version V2 ...
Page 6: ...V0606 0 6 ...
Page 50: ...V0606 2 30 ...
Page 75: ...Delem V0606 5 5 5 e ...
Page 78: ...V0606 5 8 ...
Page 86: ...V0606 6 8 6 i ...
Page 100: ...V0606 6 22 ...
Page 144: ...V0606 10 6 Functions screen 10 d Graphical visualisation 10 e ...