Multi-instrument Communication, 

MIC-2 MKII DIN Quick Start Guide

•  Warnings and legal information
•  Installation and terminals
• Communication
•  I/O options
• Alarming
•  Utility software
•  More information
• Specifications

DEIF A/S · Frisenborgvej 33 · DK-7800 Skive · Tel.: +45 9614 9614 · Fax: +45 9614 9615 · [email protected] · www.deif.com

DEIF A/S · Frisenborgvej 33 · DK-7800 Skive · Tel.: +45 9614 9614 · Fax: +45 9614 9615 · [email protected] · www.deif.com

DEIF A/S · Frisenborgvej 33 · DK-7800 Skive · Tel.: +45 9614 9614 · Fax: +45 9614 9615 · [email protected] · www.deif.com

Document no.: 
4189320056C

Summary of Contents for MIC-2 MKII

Page 1: ...ommunication I O options Alarming Utility software More information Specifications DEIF A S Frisenborgvej 33 DK 7800 Skive Tel 45 9614 9614 Fax 45 A S Frisenborgvej 33 DK 7800 Skive Tel 45 9614 9614 F...

Page 2: ...rous currents and voltages Therefore the installation should only be carried out by authorised personnel who understand the risks involved in working with live electrical equipment CE marking The unit...

Page 3: ...t can be installed into an IEC 92 mm DIN square or an ANSI C39 1 4 round form Terminals Ground terminal connection Ground can be connected to ground on a grounded system star point on the generator is...

Page 4: ...length of the Modbus cable cannot exceed 1000 m When multiple units are connected serially on the same RS485 Modbus each unit must be assigned a unique device address This address can be any integer...

Page 5: ...O Two modes available control latch or pulse and alarm output latch only One module can only support one mode at a time In control mode relays can be switched on and off from the utility software In a...

Page 6: ...lity software Please refer to the I O modules user s manual chapter 3 for operation details AXM IO2 has two analogue outputs Please notice that functionality is limited compared to traditional transdu...

Page 7: ...for the first minute after the meter is powered on The device address and the baud rate of the meter will change to the user defined values after the first minute Utility software The free utility sof...

Page 8: ...l frequency and range 50 60 Hz 45 Hz to 65 Hz Current inputs Nominal current 5 A Overload capacity 10 A continuously 100 A for 1 s FCT inputs Nominal voltage 100 mV Frequency Nominal frequency 50 60 H...

Page 9: ...Voltage inputs Nominal voltage UN L N 400 V AC L L 690 V AC Overload capacity 1500 V continuous 3250 V for 1min Nominal frequency and range 50 60 Hz 45 Hz to 65 Hz DEIF reserves the right to change an...