background image

Note about accuracy  

As this is a special version of the BRW-2 with additional circuits to simulate BRW-1 
operation, the standard specified accuracy (Class 0.5) is not met. 
 
BRW-2 Replacement is specified to: Class 1.0. 
 

Future replacement 

For future replacement, it is not necessary to replace the entire BRW-2 indicator. It may 
be sufficient to change the XL192 indicator part (the top part of the product). This will 
facilitate reinstallation. 
 
Please note that when replacing the XL192 indicator built into the BRW-2, the measuring 
range is either 0 to 1 mA or ±1 mA. Please refer to the type label on the XL192 indicator.  
 
 
 
 
 
 
 

 

 

QUICK GUIDE

BRW-2 Replacement for BRW-1 

 

Refer to www.deif.com for complete documentation

 