24.03.2017
ASSEMBLY AND OPERATING MANUAL DEGERtracker D60H, D80, D100
Page 13
2.5.2
Machines to be provided by the customer
- Hoisting gear to unload transport vehicles (forklift truck, crane, etc.)
- Crane with 4-strand lifting tackle of at least 6 m length, load bearing capacity min. 1500 kg (0-45°), to lift the
rotating head with the mounted base frame
- Ladder, working platform to assemble rotating head, elevation drive and MLD-control. Strict compliance
with national regulations is mandatory
- GPS-receiver or compass
- Cordless drill and cordless screwdriver
2.6
Technical data
D60 H
D80
D100
Nominal output
(depending on module type)
4,000 … 7,000 Wp
6,000 … 10,000 Wp
8,000 … 12,000 Wp
Module surface up to
40 m²
53 m²
70.6 m²
Max. module surface up to (WxH)
8.3 m x 5.3 m
10.05 m x 5.6 m
11.95 m x 6 m
East - West rotation angle
300°
Angle of elevation (horizontal)
0° … 80°
Control
DEGERenergie MLD
IP-protection class
IP 54/CAT 2 / UL50 Type 3R
Input voltage
100…240 VAC /50…60 Hz
Input rated current
0.3 A
Output voltage
24VDC
Max. continuous output current
2.5A
Power nominal
Control mode
1 Watt
with running drive
24V / 0.4A / 10 Watt
24V / 0.6A / 15 Watt
24V / 0.7A / 18 Watt
Internal consumption per year
approx.
12 kWh
14 kWh
16 kWh
Drive AZ
Gear in drive head
Rotating speed AZ
30°/min
Drive EL
800 mm lift
Rotating speed EL
13°/min
Sound level
less than 70 dB(A)
Materials
Stainless steel, aluminum,
steel, plastic
Length of mast tube
3.40 m … 8.0 m
3.40 m … 8.0 m
4.0 m … 8.0 m
Weight (without mast/aluminum)
890 kg
930 kg
970 kg
Article No.
MLD-D60H
MLD-D80
MLD-D100
2.6.1
Climatic conditions according to DIN EN 50178:1998-04:
Installation above sea level
max. 2,000 m
Permissible ambient temperature
-20 °C to +50 °C
Extended humidity range
0 to 95 %
Extended air pressure range
70 kPa to 106 kPa
Snow load DEGERtracker D80 and D100
max. 10 kg/m²
Snow load DEGERtracker D60H
max. 35 kg/m²
Dynamic wind pressure
0.5 to 1.35 kN/m² depending on terrain topography, mast
length, module configuration and wind zone.
2.6.2
Permitted tolerances
The horizontal SAFE position (table position) can have a tolerance of ±5°.