background image

 

 

 

operating manual

fireplace with water system

DEFRO HOME RIVA series

  

SM 

 ME 

 LA 

 

 

 

BL 

 

BP 

SHORT 

translation of original operating manual 
issue 9 
June 2020 

Summary of Contents for NAVI G

Page 1: ...operating manual fireplace with water system DEFRO HOME RIVA series SM ME LA BL BP SHORT G translation of original operating manual issue 9 June 2020...

Page 2: ...m kominkowym w przypadku odst pienia w asno ci innej osobie This Declaration of Conformity becomes invalid if any changes have been made to the DEFRO HOME RIVA Fireplace if its construction has been c...

Page 3: ...f the Warranty Card to the following address DEFRO Sp z o o Sp k Centrum Serwisowe Ruda Strawczy ska 103a 26 067 Strawczyn fax 41 303 91 31 serwis defro pl By sending back your Warranty Card you will...

Page 4: ...5 Low temperature corrosion 15 7 CLEANING AND MAINTENANCE 15 7 1 Basic operations and cleaning by the user 15 7 2 Cleaning before each starting 16 7 3 Window panel cleaning 16 7 3 1 Doors gaskets 16 7...

Page 5: ...marked in this way 2 BASIC SAFETY RULES 2 1 SAFETY WARNINGS The national and local provisions should be met Equipment should be installed in compliance with the legal standards applicable in the give...

Page 6: ...et located at the back of the equipment ADDITIONA INFORMATION In case of any problems you should contact sales out let or qualified personnel authorized by DEFRO Re quest original spare parts if the r...

Page 7: ...stment of air inflow 23 air intake socket Fuel is combusted on the cast iron grate 8 installed on the base Ash pan container 9 is located under the grate Deflector 15 is lo cated over the combustion c...

Page 8: ...icture 8 Projections with dimensions of DEFRO HOME RIVA SM G fireplace insert 246 194 1080 1413 465 564 316 135 124 842 544 947 67 104 373 105 165 870 965 113 48 170 420 300 225 225 57 37 907 698 316...

Page 9: ...OME RIVA ME BP G fireplace insert 194 966 1413 483 326 674 778 551 124 16 575 242 135 217 700 944 113 90 48 576 400 175 80 80 175 51 37 26 177 88 194 1301 1413 483 326 842 946 551 124 16 575 242 135 2...

Page 10: ...et wood with low calorific value decreases the efficiency and has an adverse influence on dry stove lifetime It is not recommended to use softwood and resinous woods as a fuel It causes intensive smok...

Page 11: ...Flooring in the room where the stove is to be installed should be properly dimensioned to maintain the load To ensure correct operation of fireplace insert you should ensure suitable inflow of air re...

Page 12: ...n the internal and external side for this purpose Furthermore the air intake should be directly connected with the room where the fireplace insert is to be installed protected with grille metal net or...

Page 13: ...ter system in the DEFRO HOME RIVA fireplace insert is equipped with two supply and two return sockets so it is possible to select hook up points to the central heating system For the correct and effec...

Page 14: ...ireplace with the water system to the old central heating system user should carry out flushing to remove sludge remaining in the radiators and pipes Fill the system with water prior to firing up of t...

Page 15: ...not allowed to damp a flame by pouring it with water because it may damage components of the equipment After a longer break in equipment s operation you should check flow capacity of the flue 6 5 LOW...

Page 16: ...1 DOORS GASKETS Abrasive surfaces of doors and closing mechanism should be oc casionally lubricated with graphite grease Carry out inspection and cleaning of the whole stove prior to each heating sea...

Page 17: ...ottom pin of the hinge is outside the frame 5 Lower the doors to ensure that the upper pin of the hinge leaves the upper opening of the frame and remove the doors 7 6 WINDOW PANEL DISMANTLING It is po...

Page 18: ...e front One side of the deflector should be in free space between the shifted beam rear and side wall of the fireplace and lower free end of the deflector Remove deflector in such position Disassembly...

Page 19: ...ll find the most frequent causes of incorrect of the equipment with their solutions Smoke draw back when the doors are opened the too rapid opening of the doors open the doors slowly if chimney damper...

Page 20: ...uids must not be used for torching the fuel only solid fuel e g tourist paper can be used etc 4 Flammable materials must not be placed on the fireplace insert and in its vicinity 5 During the fireplac...

Page 21: ...ith one free of faults 16 The product can be replaced if the Guarantor decides it cannot be repaired 17 The Guarantor does not accept liability for the inappropriate choice of product with respect to...

Page 22: ...in this period cannot constitute a ground for any claims against DEFRO Sp z o o Sp k and Au thorized Service Partner 7 To facilitate contact with service service hotline for Customers has been set up...

Page 23: ...he equipment has been delivered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manua...

Page 24: ...24 14 CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE No date fault description repaired element description of repairs comments Stamp and signature of Service 1 2 3 4 5 6 7 8 9 10...

Page 25: ...he equipment has been delivered as complete the device showed no failure during the first start up carried out by a service company has received the Operating Manual and equipment s installation manua...

Page 26: ...26...

Page 27: ...ian about fault hour Name and surname of a service technician The way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date The justness of com...

Page 28: ...28...

Page 29: ...ian about fault hour Name and surname of a service technician The way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date The justness of com...

Page 30: ...30...

Page 31: ...nician about fault hour Name and surname of service technician Way of fault removal Advice DESCRIPTION END OF COMPLAINT Name and surname of service technician Fault removal date The justness of compla...

Page 32: ...32...

Page 33: ...33 19 REGISTER OF INSPECTIONS OF SMOKE DUCTS date stamp and signature of a chimneysweep date stamp and signature of a chimneysweep...

Page 34: ...4 mg m3 13 O2 PN EN 13229 2002 PN EN 13229 2002 A1 2005 PN EN 13229 2002 A2 2006 OGC emission in combustion products 73 mg m3 13 O2 Commission Regulation EU 2015 1185 NOx emission in combustion produc...

Page 35: ...13229 2002 PN EN 13229 2002 A1 2005 PN EN 13229 2002 A2 2006 OGC emission in combustion products 77 mg m3 13 O2 Commission Regulation EU 2015 1185 NOx emission in combustion products 152 mg m3 13 O2 C...

Page 36: ...13229 2002 PN EN 13229 2002 A1 2005 PN EN 13229 2002 A2 2006 OGC emission in combustion products 83 mg m3 Commission Regulation EU 2015 1185 NOx emission in combustion products 189 mg m3 Commission R...

Page 37: ...A SM SHORT DEFRO HOME RIVA SM BL SHORT DEFRO HOME RIVA ME SHORT DEFRO HOME RIVA ME BL SHORT DEFRO HOME RIVA LA SHORT Energy efficiency class Direct thermal power kW 8 1 9 4 10 2 Indirect thermal power...

Page 38: ......

Page 39: ......

Page 40: ...DEFRO Sp ka z ograniczon odpowiedzialno ci Sp ka komandytowa 00 403 Warszawa ul Solec 24 253 Manufacturing plant Ruda Strawczy ska 103 A 26 067 Strawczyn tel 41 303 80 85 biuro defro pl NIP 9591968493...

Reviews: