REASSEMBLING THE BUTTERFLY VALVE: 

This operation is carried out in the reverse order to disassembly. The following guidelines 
should, however, be followed: 

 

Apply a suitable grease to the guides of the butterfly disc [8], the ½ bodies [9] and the 
seal [7]. 

 

Keep the butterfly disc [7] in a closed position while tightening the ½ bodies in order 
to properly centre the seal [7]. 

 

  1.10  

ASSEMBLING THE VALVE AND THE OPERATING SYSTEM: 

 

This operation is also carried out in the reverse order to disassembly. The following 
guidelines should be followed for the automatic system: 

 

Do not forget to fit the position pointer [45] and in particular to check the N.C or  N.O valve 
operating position (position of drive squares). 

 

Before making the final network connections, check that the valve is operating normally. 

 

If you encounter problems when carrying out the operations described below, do not 
hesitate to contact us. 

 

NOTE:

 We  also  remain  at  your  disposal  to  maintain  your  valves  either  on-site  or  at  our 

own premises. 

NOTE ! 

Summary of Contents for DPAX1 AUTOMATIC

Page 1: ...MAINTENANCE NOTICE IT TDFX 222 Revision 0 Page 1 16 October 2008 MANUAL AND AUTOMATIC INTERFLANGE BUTTERFLY VALVES www definox com...

Page 2: ...7 DISMANTLING THE OPERATING SYSTEM 7 1 5 DISMANTLING THE MANUAL SYSTEM 7 1 5 1 DPX1 EBC with detection trigger adjustment 7 1 5 2 DPX1 micrometric adjustment 8 1 6 DISMANTLING THE AUTOMATIC SYSTEM 8 C...

Page 3: ...MAINTENANCE NOTICE IT TDFX 222 Revision 0 Page 3 16 October 2008 CHANGE MANAGEMENT CHANGES INDEX DATE PAGE S INITIALS...

Page 4: ...s bodily injury or loss of life This can also result in less serious injuries or damage to the equipment Electricity can result in serious bodily injury or loss of life This can also result in less se...

Page 5: ...ivided into three distinct steps DISASSEMBLING THE VALVE Before starting the disassembly procedure if the valve is fitted with a signalling box it may be necessary to detach the signalling unit from t...

Page 6: ...system For the micrometrically adjustable valve take care not to lose the spacer 38 1 4 2 SEPARATING THE AUTOMATIC SYSTEM Unscrew the four valve half body 9 fastening screws 43 Disconnect the actuator...

Page 7: ...wo bodies 9 take off Take off the wearing rings 6 and remove the butterfly disc 8 from the seal 7 DISMANTLING THE OPERATING SYSTEM 1 5 DISMANTLING THE MANUAL SYSTEM 1 5 1 DPX1 EBC with detection trigg...

Page 8: ...move screw 41 then slightly unscrew the control handle assembly 32 33 and remove the drive wheel 40 unscrew the lock screw 35 pull the operating handle 32 33 from the body 36 1 6 DISMANTLING THE AUTOM...

Page 9: ...OPERATING SYSTEM This procedure is performed in the reverse order to dismantling However it is necessary to take into account the following comments for the automatic system Before reassembling the pa...

Page 10: ...1 10 ASSEMBLING THE VALVE AND THE OPERATING SYSTEM This operation is also carried out in the reverse order to disassembly The following guidelines should be followed for the automatic system Do not fo...

Page 11: ...1 7002775 1 7003467 2 2 4 1 4 7003477 2 7003487 2 2 2 1 7002775 1 7003467 2 2 4 40 4 7003477 2 7003488 2 2 2 1 7002775 1 7003467 2 2 4 51 4 7003478 2 7003489 2 2 2 1 7002776 1 7003468 2 2 4 2 4 70034...

Page 12: ...6585 7006586 7006601 80 7006593 7006594 7008786 104 100 4 7006637 7006638 7006662 125 7006555 7006556 7006579 150 6 7008546 7008543 1 13 BODY SEALS 10 DN VMQ FKM EPDM SMS DIN US 25 25 1 7011010 700626...

Page 13: ...ENANCE NOTICE IT TDFX 222 Revision 0 Page 13 16 October 2008 1 14 STANDARD MANUAL HANDLE Right hand opening Left hand opening Right hand opening Left hand opening Low level detection Micrometric adjus...

Page 14: ...r hub right hand opening 1 7003177 7003179 24 Trigger hub left hand opening 1 7003180 7003181 25 Low level sensor disc 1 7003519 7003520 7003521 7003522 7003523 7003524 7003525 7003556 7003557 26 Sens...

Page 15: ...17 LIST OF PARTS FOR AUTOMATIC CONTROL ACTUATOR Ref Part name Qty DN25 to 80 DN104 DN125 to 150 42 Fastening bracket 2 7003506 7003507 43 Hex Screw 4 7006939 7812760 44 CHC screw 4 7006817 7380374 45...

Page 16: ...DEFINOX Beijing Stainless Steel Equipment Ltd No 18 Anningzhuang East Road HAIDIAN District BEIJING 100085 CHINA Tel 86 10 6293 4909 Fax 86 10 6293 4835 lk definox com cn The product specifications c...

Reviews: