DeepSea Power & Light IP Multi SeaCam IPMSC-3070 Operator'S Manual Download Page 4

4

IP Multi SeaCam

®

Safety Symbols

In this operator’s manual and on the product, safety symbols and signal words communicate 

important safety information. This section is provided to improve understanding of these signal 

words and symbols.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol 

to avoid possible injury or death.

DANGER

 

indicates a hazardous situation which, if not avoided, could result in death or serious injury.

WARNING

 indicates a hazardous situation which, if not avoided, could result in damage to the product or bodily harm.

CAUTION

 indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

 

NOTICE 

indicates information that relates to the protection of property.

This symbol means read the operator’s manual carefully before using the equipment. The operator’s manual contains important 

information on the safe and proper operation of the equipment.

This symbol means always wear safety glasses with side shields or goggles when handling or using this equipment to reduce the risk of 

eye injury.

This symbol indicates the risk of electrical shock.

This symbol indicates the risk of electrostatic discharge (ESD). Always use ESD safe practices when handling equipment.

 

This symbol indicates a potentially hot surface that may cause burns or ignition.

  

 

CAUTION

NOTICE

DANGER

WARNING

General Safety Information

Do not operate any high voltage electrical equip

-

ment in or around water without using a Ground 

Fault Circuit Interrupter (GFCI) and an isolation 

transformer, especially when divers are in the water.

Never place the camera in a vice or other hard 

clamping tool. Should it become necessary to hold 

the camera tighter than can be managed by hand, 

use a clean, good quality strap wrench.

Equipment Use and Care

 

The IP Multi SeaCam supports a variety of con-

nectors. Verify pinout orientation before use.

 

Before deployment, check that the rear bulkhead 

connector assembly is secure. Check that the 

connectors are fully seated and that the seals are 

engaged. Failure of the strain relief provisions 

may damage the connectors and other elements 

of the system.

 

Before and after each deployment, check the fol-

lowing areas for damage, wear or corrosion:

a.  Rear bulkhead connector assembly

b.  Video cable

c.  Front Window

d.  Retaining cowl

 

Rinse the Apex SeaCam in fresh water after use 

in saltwater.

After each deployment, carefully check to make sure 
the camera has not flooded.  It is possible for the 
camera to partially flood and then reseal itself while 
underwater.

DANGER

WARNING

WARNING

Summary of Contents for IP Multi SeaCam IPMSC-3070

Page 1: ...his Operator s Man ual carefully before using this tool Failure to under stand and follow the con tents of this manual may result in electrical shock fire and or serious per sonal injury Original Instructions English 1 IP Multi SeaCam ...

Page 2: ...t 5 System Setup 5 Controls and Operation 5 Power Over Ethernet and DC Power 5 SD Card Formatting 5 Camera Controls and Indicators 5 Record Playback and Download 5 SeaSense Protocol Information 5 Web Based User Interface 6 Maintenance and Repair 6 Flooding Repair Procedure 6 Troubleshooting 7 RMA Procedure for Repair 7 Warranty Information 7 Limited Warranty 7 Appendix A SeaSense Serial Interface ...

Page 3: ...BD Storage Temp 30 C to 70 C 22 F to 158 F Electrical Specifications Voltage 10 36 VDC Power Over Ethernet IEEE802 3af Power 2W max Mechanical Specifications Housing Titanium Port Sapphire Borosilicate Glass Outer Diameter 56 4 mm 2 22 in 69 1 mm 2 72 in Overall Length 102 8 mm 4 05 in 124 mm 4 88 in Weight in Air TBD TBD Weight in Water TBD TBD Connector Default SEACON MCBH8 NET Please contact sa...

Page 4: ...cates the risk of electrostatic discharge ESD Always use ESD safe practices when handling equipment This symbol indicates a potentially hot surface that may cause burns or ignition CAUTION NOTICE DANGER WARNING General Safety Information Do not operate any high voltage electrical equip ment in or around water without using a Ground Fault Circuit Interrupter GFCI and an isolation transformer especi...

Page 5: ...r Ethernet and DC Power Information about this SD Card Formatting The IP Multi SeaCam comes with a standard 256 GB micro SDXC flash memory card for onboard video and still image storage DeepSea recommends formatting the onboard memory card outside of the camera The camera has limited formatting capability and may not properly format the onboard memory from the web user interface The microSDXC memo...

Page 6: ...move the connector and inspect the assembly for visual signs of wear Use a multi meter check for continuity or shorts If available try a spare connector in the camera 3 Check the wires that go from the power supply to the camera base for wear If they appear worn replace them 4 Check that the power supply board is securely attached to the camera If it is loose check for damage on the board If no da...

Page 7: ...arranty will be limited to the repair or replacement of parts and the necessary labor and services required to repair the goods IT IS EXPRESSLY AGREED THAT THIS WARRANTY WILL BE IN LIEU OF ALL WARRAN TIES OF FITNESS AND IN LIEU OF THE WARRANTY OF MERCHANTABILITY This warranty is the exclusive and only warranty to pass with the goods under this contract No agent employee or representative of the Se...

Page 8: ...this document is confidential and proprietary to DeepSea Power and Light LLC No license expressed or implied under any patent copyright or trade secret right is granted or implied by the conveyance of this document No part of this document may be reproduced transmitted transcribed stored in a retrieval system translated into any language or computer language in any form by any means electronic mec...

Page 9: ...nterface TeraTerm is recommend when connected through a USB port Please reference DSPL_virtualComPort http www deepsea com wp content uploads DSPL_virtualComPort zip documentation for installing the device driver if operating via a USB port Instruction 1 Changing the device over the RS232 RS485 interface requires Factory Unlocked mode If you are connected directly via the USB skip to step 2 To ent...

Page 10: ...w The example response above indicates that the device is set to RS232 at 9600 baud rate 3 Send 001 FPRT RS4 1 to set the device to RS485 at the default 9600 baud rate To set RS485 at a different baud rate enter 001 FPRT RS4 2 for 19200 baud rate 001 FPRT RS4 3 for 57600 baud rate To set the device to RS232 enter RS2 in place of RS4 001 FPRT RS2 1 for 9600 baud rate 001 FPRT RS2 2 for 19200 baud r...

Page 11: ...11 Operator s Manual ...

Page 12: ...20 DeepSea Power Light All rights reserved Rev 05 28 2020 Printed in USA DeepSea Power Light www deepsea com 4033 Ruffin Road sales deepsea com San Diego CA 92123 181 T 1 858 576 1261 USA F 1 858 576 0219 ...

Reviews: