background image

mPULSE3000

®

 

Pool water treatment system 

 

 

Instruction & Owner’s Manual 

 

Summary of Contents for mPULSE3000

Page 1: ...mPULSE3000 Pool water treatment system Instruction Owner s Manual ...

Page 2: ...oltage Connection Instructions 4 Instructions for use with Salt Water Generator 5 Instructions for Voltage Manual Select Switch 6 Field Installation Instructions 7 Trouble Shooting 8 Regular Maintenance Specifications 9 10 Warranty Registration 11 877 882 4695 ...

Page 3: ...he load side of the timer only to run with the circulation pump a The length of the cable from the chamber to the Electronic Control Box CANNOT be lengthened or shortened it is a specific length to ensure that the impedance of the chamber is matched properly with the control head to maximize calcium scaling prevention b The AC power connection from the electronic control head to the timer is the r...

Page 4: ...AGE CONNECTION INSTRUCTIONS SIMPLY FIT THE FEMALE END OF THE PLUG ON THE LOW VOLTAGE CABLE THAT CONNECTS TO THE CHAMBER ONTO THE MALE END ON THE ELECTRONIC CONTROL BOX WHICH IS LOCATED ON THE UNDERSIDE OF THE BOX ...

Page 5: ...oving the three screws holding it on You will see the equivalent of the above diagram Note the switch labeled A and B Standard position is A This will be used for swimming pools with standard sanitization chlorine etc For use with a Salt Water Chlorine Generator and high conductivity pools change the switch to the B position Either position can be used to decalcify pool Unit will keep salt generat...

Page 6: ...it is 220 230V The majority of swimming pool equipment sets are provided with 220 240V electrical power If you come across a swimming pool that instead utilizes 100 120V power please use the following instructions 1 Using a flat head screwdriver place it in the slot in the Voltage Select Switch currently labeled 230V 2 Move the Voltage Select Switch to the left carefully until it reaches the far l...

Page 7: ...size UL Listed conduit fitting into 7 8 diameter opening and tighten install in accordance with the fitting s instructions Fitting and conduit should be suitable for the installation environment such as liquid tight conduit and installed in compliance with all applicable local ordinances and the NEC a The AC INPUT terminal can handle COPPER wire 8 to 18 AWG solid or stranded 3 Pull new copper wiri...

Page 8: ...amber Lack of proper water flow will lead to a Red Function light 3 Ensure that there are no shorts or opens in the Chamber cord 4 Change to alternative conductivity switch position if red LED remains illuminated 5 Have you recently treated the pool with muriatic acid or chlorine This could change the conductivity of the water leading to a red light Wait for 48 hours and check again 6 Check chemis...

Page 9: ... This includes a regular weekly maintenance schedule consisting of but not limited to maintaining a pH level between 7 2 and 7 6 maintaining an Alkalinity level between 80 to 120 PPM Maintenance should also include regularly brushing the water line spillways tile and water features as well as any other calcium plagued areas of the swimming pool Generally Muriatic Acid is used in swimming pools to ...

Page 10: ... Output Voltage 50Vpp Max Output Current 350mA RMS Output Frequency 4 1 KHz 0 1 KHz Max Temperature 140º F 60º C Weight 6 Lbs or 2 72 kg Size 9 x 5 x 4 Mechanical Torque 16 in lbs Wire Range 8 18 AWG Insulation Strip length 5 16 IMPORTANT NOTE The mPULSE3000 does not remove calcium and due to evaporative conditions calcium will still be visible in SPLASH ZONES around water features zero edge pools...

Page 11: ...e of your pool spa and or water feature along with your regular weekly chemical and maintenance service Detach Here MPULSE 3000 Pool Water Treatment System WARRANTY REGISTRATION CARD must be returned to activate Date of Purchase____________________________________________________ Serial Numbers Control Box________________Chamber ________________ Under metal plate 6 digit number attached to chamber...

Reviews: