17
4.4
FIXING THE MOUNTING RAILS
(panels side by side)
1. Fit the mounting rail (04) onto the roof anchors (03).
To do so, turn the heads of the interlock bolts (10)
parallel to the mounting rail (04) and place the
mounting rail over them.
Push the interlock bolts upwards through the roof
anchor (03) and turn through 90° (
) to secure.
These bolts must be aligned before they are tight-
ened. Then finger-tighten the nuts on the interlock
bolts. Remember to fit the serrated washers to the
interlock bolts.
2. Align the mounting rails horizontally and vertically
so that the rails run parallel to the roof tiles. The di-
agonals between the mounting rails must be equal,
i.e.
D1 = D2
Use the slotted holes to set the mounting rail centre-
to-centre distance to 1670 mm.
Tighten the nuts on the interlock bolts after the rails
have been aligned.
Fitting the panels:
see Kapitel 6. Kollektor-Montage, Seite 26.
GB
04
10
03
8980N219
8980N220
D1
D2
1670