■ Installation with boiler equipped with any other panel
Fig.31 Example 2
NIU-013
1
4
2
3
5
6
7
8
1
Relay
2
Clock
3
Double-pole summer-winter switch
4
Control panel with domestic hot water control
5
Domestic hot water load pump
6
Domestic hot water control sensor
7
MPLC combination water heater
8
Immersion heater
Note
The double-pole ”Summer-Winter” switch enables either
immersion heating (Summer) or boiler heating (Winter).
If you want to be able to control both heating modes separately,
simply replace the switch with two independent On/Off switches.