5.9.3.
Connecting the DHW heating pump
Connect the DHW heating pump to the corresponding terminal block
on the boiler (Terminal X4).
¼
See chapter: "Terminal block", page 22
5.9.4.
Connecting the plate exchanger outlet
Connect the domestic hot water temperature sensor cable to the
corresponding terminal block on the boiler (Terminal X20).
¼
See chapter: "Terminal block", page 22
5.9.5.
Connecting the impressed current anode
1. Remove the inspection trap insulation.
2. Connect the connectors on the titanium anode cable.
3. Put the inspection trap insulation back in place, feeding the cables
into the notches.
4. Route the cable through the cable feed-through to the back of the
DHW tank.
5. Connect the titanium anode cable to the corresponding terminal
block on the boiler (Terminal TA-).
¼
See chapter: "Terminal block", page 22
L000232-D
1
M002412-C
1
2
2
3
4
5. Installation
100 HL
21
22/08/2014 - 300026877-001-02