DeDietrich DHD585XE1 Installation Manual Download Page 7

2/ INSTALLING THE HOOD

EN

- During installation, or in the case of repairs, the appliance must be unplugged.

- Make sure that the electrical tension of the power source corresponds to the electrical tension 

indicated on the information plate on the inside of the hood.

-If you need to modify the electrical layout of your house in order to be able to use the hood, 

call a qualified technician.

- If you use the hood in the discharge mode, never hook up the appliance to a discharge conduit used 

for combustion fumes (boilers, chimneys, etc.) or a CMV unit (Controlled Mechanical Ventilation).

- The discharge conduit, whatever it may be, must never exit into the attic.

- Install the hood at a safe distance of at least 70 cm from the hob surface, whether they are 

electric, gas, or mixed.

If you have a conduit exit to the outside: 

fig. 2

The hood can be hooked up to the opening by way of a discharge conduit (minimum diameter 

F125mm, unpainted, in aluminium, flexible, or in non-flammable material).  If the conduit has 

a diameter of less than 125 mm, you must use the hood in the recirculation mode.

If you do not have a conduit exit to the outside: 

fig. 1

All of our appliances can operate in the recirculation mode.

In this case, you must add an active carbon filter that acts to control smells.

ELECTRIAL HOOK UP

 

This appliance conforms to the European Directives 2006/95/EC (Low Voltage Directive) 

and 2004/108/EC (Electromagnetic Compatibility).

When you install the appliance and carry out maintenance, it must be unplugged from the power 

source or the fuses must be disengaged or removed. Electrical hook up must be carried out 

before the appliance is installed in the cabinet.

Check that:

- the power source is sufficient,

- power cords are in good condition,

- The diameter of the cables conforms to installation regulations.

- MOUNTING THE HOOD

 

Installation must conform to the regulations in force regarding the ventilation of 

enclosed environments. In France, these regulations are container in the DTU 61.1 of the 

CSTB. In particular, discharged air must not be channelled into a conduit used for exhaust 

discharge or discharge from devices that operate with gas or other combustible materials. 

The use of unused conduits is not permissible without the approval of a qualified tech

-

nician. The minimum distance between the hob surface and the lowest part of the hood 

must be 70 cm.  IF the instructions for the cooker installed under the hood require an even 

greater distance, this must take precedence.

- INSTALLATION

Before installing the hood, remove the anti-grease filters to avoid damaging the appliance.  To 

remove the anti-grease filters, push the handle toward the lower part of the hood and rotate the 

filter downward, removing it from its housing (Fig. 3A).

Attention: Installation must be carried out by at least two people.

Before installing the hood, ensure a supply of electricity to the conduit and the discharge hole, 

in the case of an installation with discharge.

34

Summary of Contents for DHD585XE1

Page 1: ...ITÍ PL INSTRUCJA OBSŁUGI HU HASZNÁLATI UTASÍTÁS EL ΕΓΧΕΙΡΙΔΙΟ ΧΡΗΣΗΣ DA BRUGERMANUAL SK PRÍRUČKA NA POUŽITIE Hotte décor Digestoř Dekor Dunstabzugshaube Wyposażenie okapu Decorative Hood Szagelszívó berendezés Campana extractora decorativa Διακοσμητικός Απορροφητήρας Cappa arredamento Indretnings emhætte Designafzuigkap Digestor Exaustor decorativo Spiskåpa för innebruk DHD585XE1 DHD783X ...

Page 2: ...2 ...

Page 3: ... be freely coordinated with your new DE DIETRICH range ventilation hood Naturally since our objective is the satisfaction of our clients towards our products our customer service is at your total disposition to respond to any request and receive any useful suggestion reference details at the end of the booklet Visit our web site www dedietrich elecromanager com where you will find our latest innov...

Page 4: ...ianc 33 2 INSTALLING THE HOOD Mounting the hood 34 Installation 34 Removal of the filter cartridge 35 Mounting the carbon filter 35 Electrical hook up of the hood 36 3 HOW THE HOOD WORKS 37 4 CLEANING THE HOOD 39 5 OPERATIONAL ANOMALIES Changing the light bulb 40 6 AFTER SALES SERVICE 40 31 ...

Page 5: ...ore carrying out cleaning or maintenance operations Adequately ventilate the area in case the hood is activated simultaneously with other applian ces powered from non electrical sources so that the hood does not ventilate these combustion fumes It is prohibited to cook food over open flames or operate gas hobs without pots or pans on them under the hood itself the flames sucked into the hood might...

Page 6: ...1 TO THE ATTENTION OF THE USER EN DESCRIPTION OF THE APPLIANCE 33 A air output grill filter mode B ventilation pipe C display A B C DHD585XE1 DHD783 A B C ...

Page 7: ...e and 2004 108 EC Electromagnetic Compatibility When you install the appliance and carry out maintenance it must be unplugged from the power source or the fuses must be disengaged or removed Electrical hook up must be carried out before the appliance is installed in the cabinet Check that the power source is sufficient power cords are in good condition The diameter of the cables conforms to instal...

Page 8: ...1 Fig 5 2 Fig 11 with the safety screws Fig 5 2A Connect the hood conduit to the air discharge hole Then insert the two telescopic pipes fig 6 4 e 6 5 into the lower part of the hood Fig 12 Before inserting the telescopic pipes completely Fig 6 4 e 6 5 hook up the display connection Fig 13 Then lift the conduit completely and attach it to the hood with the supplied screws Fig 12 A Raise the upper ...

Page 9: ...ust remain accessible after installation in conformity to installation regulations We decline all responsibility in case of accident caused by a lack of ground connection or incorrect ground connection The fuse used must be 10 or 16 A If the power cable is damaged call the after sales service to avoid any risk Attention If the hood presents some form of anomaly unplug the appliance or remove the f...

Page 10: ...ourth one press the button To reduce the speed up to the second one press the button To go from a high speed back to the first one press twice the button To light on or to light off the hood press the button To set the timer up press the button The LED on the right side will start to flash every 5 seconds the hood will work for 10 minutes at the selected speed and then it lights automatically off ...

Page 11: ...DS will flash 3 times to indicate that the process is completed WARNING This procedure deletes all previously stored codes Learning the new transmission code After changing the transmission code on the radio control the cooker hood electronic control unit must be made to set the new code as follows press the main Power Off button on the cooker hood and then restore power to the electronic control ...

Page 12: ...is message by pressing the timer switch To remove the anti grea se grill push the handle toward the back of the hood and rotate the grill downward removing it from its hou sing To replace the grill do the re verse To clean the grill wash it by hand or in the washing machine Clean it at least every two months Active carbon filter In the recirculation mode you must substitute the active carbon filte...

Page 13: ...ore any maintenance the hood must be disconnected from the power source either by unplugging the power cord from the wall socket or by deactivating the switch Dichroic light bulb To substitute the halogen bulb remove it by sliding a small screwdriver or a sharp utensil between the bulb and its housing Replace the bulb with another of the same specifications fig 7 Any maintenance on your equipment ...