4. Standard vertical wall-mounted water heaters

Type of water heater                      STANDARD VERTICAL WALL-MOUNTED HEATER

Nominal capacity

litres

50

75

100

150

200

Nominal power

watts

900

1200

1200

1800

2400

Heating time (1)

3:55 hr. 4:30 hr. 5:30 hr. 5:25 hr. 5:30 hr.

Maintaining consumption

kWh per 24 hours at 65˚C (2)

0.72

0.78

0.96

1.11

1.33

Cooling constant

Wh per 24 hours / litre / ˚C

0.35

0.24

0.23

0.18

0.17

Category (as per 1989 
Thermal Equipment regulations) 

B -20 % B -20 % B -20 %

Main dimensions

A

mm

156

120

113

146

473

B

mm

500

800

800

D

mm

370

572

750

1050

1050

H

mm

576

742

913

1246

1573

H with optional stand

mm

1234

1405

1738

2065

Weight without water

kg

23

29

33

43

52

(1) As per standard NFC 73 221 (15˚C to 65˚C). 

(2) As per French Standard.

Fastening

Vertical wall-mounted water heaters are fastened with 4 bolts, dia.

10, sealed into the wall.
A drilling template is supplied with the unit to make it easier to mark

the drilling holes without any need to take measurements.
Two clamps fitted with notches (supplied with the unit) allow easy

fastening. The heater is packed upside down and placed on a poly-

styrene packing piece. In this way, the various parts are kept acces-

sible and it is easier to fit the clamps.

(*) Note: 50 L and 75 L heaters are fastened with only two bolts. The lower
clamp is replaced by a stop.

Stand:  75, 100, 150 and 200 L Standard vertical wall-mounted
water heaters may be placed on the floor on a stand designed for
standard vertical models which is available as an option. We recom-
mend that you fasten the upper clamp to the wall.

Electrical connections

Vertical wall-mounted water heaters are designed for a single-

phase 230 VAC power supply. The coupling of multiple voltage hea-

ters is user-modifiable, and may also be set for three-phase 230 V

or 400 V power supplies.

The metal parts must be grounded (with the special terminal on the

unit). The section of the line, the omnipole breaking device and the

protection system (fuses or circuit-breakers) shall be selected in

keeping with applicable standards, depending upon the input inten-

sity, voltage and power.

Note: The heaters must necessarily be connected to a fixed piping system. In prin-
ciple, power will be supplied to the heater at night, manually or automatically with the
help of a clock supplied by the electricity company. In this way, the water is heated
when the reduced off-peak rate is charged for electricity. The unit may be fitted with a
switch for supplying power in the daytime, when the full rate is charged.

Type of water heater

STANDARD VERTICAL WALL-MOUNTED HEATER

Capacity

litres

50

75

100

150

200

Power supply

single single single single multiple single multiple

Section

mm

2

1,5

1,5

1,5

1,5

1,5

2,5

2,5

Single-phase 230 V

Intensity

Amp

3,9

5,2

5,2

7,8

7,8

10,4

10,4

Section

mm

2

1,5

1,5

Three-phase 230 V

Intensity

Amp

4,5

6

Section

mm

2

1,5

1,5

Three-phase 400 V

Intensity

Amp

2,6

3,5

Hydraulic connections

The connections are marked with blue (cold water) and red (hot
water) discs. Fitting a stop valve on the cold water supply pipe is
compulsory.

Safety rules require that a lead-sealed safety valve calibrated to 7
bar must necessarily be fitted on the cold water supply pipe (for the
guarantee to operate). We recommend the use of diaphragm type
hydraulic safety units bearing the NF mark. 

A pressure reducing

valve must be fitted if the supply pressure is greater than 5.5 bar.

Example of installation

Pressurised heater

Type of heater                               STANDARD VERTICAL WALL-MOUNTED HEATER

Capacity

litres

50

75

100

150

200

14 x 16

Copper pipe dimensions

mm

12 x 14 or 14 x 16

or

16 x 18

Note : The composite material connecting piece (supplied in a bag) is to be
fitted on the hot water outlet of the heater. It is used to prevent the formation
of a galvanic couple, which can lead to the corrosion of the connection
threads when the heater is connected directly to copper or brass.

;;

@@

;;

yy

;;

;;

@@

@@

;;

;;

yy

yy

;;

;;

@@

@@

;;

;;

yy

yy

Fastening dimensions 
in mm

Heater shown here: 100 L

Hot water outlet
pipe
(stainless steel)

Cladding in
cylindrical
enameled white
sheet metal

Thick metal tank
(test pressure 12
bar)

Heating element
made up of an
enclosed resistor
on a steatite
support, accessible
without draining the
heater.

Imposed current

titanium anode

Thimble tube

thermostat

Rigid injected

polyurethane foam

insulating material

(0% CFC)

Vitreous enamel with

a high quartz content,

resistant to the most

corrosive water

Cold water supply

pipe with anti-splash

plug (stainless steel)

Thermostat

ajustable 

including a thermal

safety device

Single-phase 230 V

power supply

connection, multiple

voltage available

with 150 and 200

litre models.

8971Q007

optional stand

Cold water 
supply R  3/4"

Hot water outlet
R 3/4"

175

528

35

440

230

= = 

H

B

A

505

D

250

NB: to enable the eventual replacement of the heating element, leave a free space at least
equal to 250 mm (50 and 75 l) /300 mm (100 l) /390 (150 l) /480 (200 l) beneath the ends of the
water heater pipes.

8978F009

8978F007

9. Stop valve

28. Cold water supply pipe
29. Pressure reducing valve
30. Safety unit set to 7 bars

a. Cold water inlet including

a non-return valve

b. Connection to the calori-

fier cold water inlet.

c. Stop valve.
d. valve and manual drain.
e. Drain orifice.

54. YA type load break (heal-

th regulations).

57. Hot water outlet

9

29

28

57

b

c

d

e

2 cm

(54)

30

a

8978F006

Summary of Contents for Cor-email

Page 1: ...plications D E D I E T R I C H T H E R M I Q U E Société Anonyme au Capital de 21 686 370 Euros BOITE POSTALE 30 57 RUE DE LA GARE F 67580 MERTZWILLER TELEPHONE 03 88 80 27 00 FAX 03 88 80 27 99 Vertical wall mounted water heaters 50 200 litre standard heaters p 4 These highly aesthetic heaters may be mounted on a wall or placed on a stand Thanks to their small dimensions they may also be fitted i...

Page 2: ...ermostats of all heaters are factory set at 65 C Selecting the water heater Hot water needs are not easy to assess as they increase very rapidly as users get used to this major convenience As a result the recommended capacity should be much greater than existing needs Daily needs Supply point Number of people hot water at 60 C Recommended capacity in the household days of normal use days of increa...

Page 3: ...guarantee to operate We recommend the use of diaphragm type hydraulic safety units bearing the NF mark A pressure reducing valve must be fitted if the supply pressure is greater than 5 5 bar Examples of installation Type of heater COMPACT HEATER COMPACT HEATER for low mounting for overhead mounting Capacity litres 10 15 10 15 30 Dimensions of AFY 40 cast female 1 2 ron pipe joints in inches male 3...

Page 4: ...CAL WALL MOUNTED HEATER Capacity litres 50 75 100 150 200 Power supply single single single single multiple single multiple Section mm2 1 5 1 5 1 5 1 5 1 5 2 5 2 5 Single phase 230 V Intensity Amp 3 9 5 2 5 2 7 8 7 8 10 4 10 4 Section mm2 1 5 1 5 Three phase 230 V Intensity Amp 4 5 6 Section mm2 1 5 1 5 Three phase 400 V Intensity Amp 2 6 3 5 Hydraulic connections The connections are marked with b...

Page 5: ...2 6 3 Three phase 400 V Intensity Amp 2 6 3 Hydraulic connections The connections are marked with blue cold water and red hot water discs Fitting a stop valve on the cold water supply pipe is compulsory Safety rules require that a lead sealed safety valve calibrated to 7 bar must necessarily be fitted on the cold water supply pipe for the guarantee to operate We recommend the use of diaphragm type...

Page 6: ...ected directly to copper or brass With 400 and 500 L heaters connection to copper piping must necessarily be done via cast iron male female reducing or non reducing pipe joints for the guarantee to operate E g _ or 1 AFY 40 pipe joints for 400 litre hea ters and 1 joints for 500 litre heaters 6 Free standing water heaters Type of water heater FREE STANDING HEATER Nominal capacity litres 150 200 25...

Page 7: ...eaters p 5 free standing water heaters except 400 and 500 l p 6 The connection of a water heater to copper mains pipes must be done using the intercalation of the insulation connector if this is delivered with the appliance or with reduced or equal male female sleeves in cast iron if this is not the case The connector provided is intended to be connected to the hot water outlet the safety control ...

Page 8: ...mounted vertical horizontal and floor standing water heaters except 400 and 500 l are fitted with the ACI system active and permanent protection of the tank against corrosion using a titanium anode which does not dissolve over time and requires no mainte nance Important Check the correct operation of the safety unit see ins tructions for use from time to time at least once a month Do not worry if ...

Reviews: