DeDietrich C 310 ECO User Manual Download Page 4

4

C 310 ECO - C 610 ECO

02/10/07 - 300015183-001-A

2 Safety instructions and recommendations

2.1 Safety instructions

„

Fire hazard

Do not stock products of an inflammable nature close to
the appliance.

If you smell gas, do not use a naked flame, do not smoke,
do not operate electrical contacts or switches (doorbell,
lights, motor, lift, etc.).

1.

Cut the gas supply

2.

Open the windows

3.

Extinguish all flames

4.

Evacuate the premises

5.

Contact a qualified professional

6.

Inform the gas supplier

„

Risk of intoxication

Do not obstruct the air inlets in the room (even partially).

In the event of flue gas emanation

1.

Switch the appliance off

2.

Open the windows

3.

Evacuate the premises

4.

Contact a qualified professional

„

Risk of being burnt

Avoid direct contact with the flame viewport.

Depending on the settings of the appliance:

- The temperature of the flue gas conduits may exceed 60°C
- The temperature of the radiators may reach 95°C
- The temperature of the domestic hot water may reach 65°C

„

Risk of damage

Do not stock chloride or fluoride compounds close to the
appliance.

Install the appliance in frost-free premises.

Do not neglect to service the appliance: Contact a qualified
professional or take out a maintenance contract for the annual
servicing of the appliance.

2.2 Recommendations

Only qualified professionals are authorised to work on the
appliance and the instalation.

Before any work, switch off the mains supply to the
appliance.

Check regularly that the installation contains water and is
pressurised.
Keep the appliance accessible at all times.
Avoid draining the installation.
The appliance should be on Summer or Antrifreeze mode rather than
switched off to guarantee the following functions:

- Antifreeze protection
- Protection against corrosion on domestic hot water tanks fitted

with a titanium anode.

Summary of Contents for C 310 ECO

Page 1: ...C 310 ECO C 610 ECO Gas fired condensing boiler User Guide 300015183 001 A EN...

Page 2: ...1 Safety instructions 4 2 2 Recommendations 4 3 Description 5 4 Use of the appliance 6 4 1 Control panel 6 4 2 Display 6 4 3 Changing the settings 7 4 4 Stopping the boiler 8 4 5 Commissioning the boi...

Page 3: ...tee the optimal operation of your appliance We are sure that it will be entirely to your satisfaction and will meet with all of your expectations Keep these instructions in a safe place close to the a...

Page 4: ...e appliance The temperature of the flue gas conduits may exceed 60 C The temperature of the radiators may reach 95 C The temperature of the domestic hot water may reach 65 C Risk of damage Do not stoc...

Page 5: ...bolt 13 Condensates evacuation pipe 14 Flue gas discharge duct 15 Inspection hatch 16 Reduction sleeve 250 200 Option 17 Heat exchanger 18 Output sensor 19 Air intake 22 Gas connection 23 Flame inspec...

Page 6: ...on the safety control card 4 2 Display 1 Text and numerical display 2 Graphic display bar for the programme in circuit A B or C 3 Light area Reduced temperature heating period or tank load disabled 4...

Page 7: ...s all the time if is steady Antifreeze mode Tank load enabled mode A 0 2 4 6 8 10 12 14 16 18 20 22 24 A STANDARD C000142_03 SUNDAY 04 Manual Summer shutdown key The heating is switched off and DHW pr...

Page 8: ...eck the setting of the gas air ratio and if necessary correct it The check is carried out at high and low speed while setting takes place only on the gas multiblock For checking and setting you will n...

Page 9: ...ional 23 Set the boiler regulation to the desired values 24 Switch the boiler on and fill in the label Set to Each individual boiler is delivered with the following fixed factory settings Natural gas...

Page 10: ...ast 1 time a year Checking the combustion in the boiler Checking the heat exchanger Checking condensates discharge Checking the ignition electrode Checking for leaks water combusted gas gas Checking t...

Page 11: ...on plate Before informing the fitter of a fault make a note of the following information Type of gas used Boiler type Date of manufacture Year 01 2001 02 2002 Week Serial no of the appliance This info...

Page 12: ...b MCBA FAILURE 30 T maxi exceeded Check the water flow MCBA FAILURE 61 Air pressostat closed Check If Faulty air pressostat If the wiring to the air pressure switch is in order If the thermal draught...

Page 13: ...ault in the gas valve faulty coil Check the wiring Check that the fuses are in good working condition PARASIT FLAME Detection of a parasite flame Check the tightness of the gas circuit Check the ignit...

Page 14: ...ve is no longer supplied It may be manually operated if necessary DHW S FAILURE Heating of domestic hot water is no longer ensured The load temperature of the dhw tank is the same as the boiler OUTSI...

Page 15: ...draulic pressure BLOCKING b26 Check the bridge between terminals X4 8 and X4 3 in the box BL DT BOI BACK he maximum difference tolerated between the outlet and return temperatures has been exceeded Th...

Page 16: ...1 7 13 4 maximum m3 h 33 1 41 3 49 7 57 9 66 3 Average nitrogen oxide emission NOx mg kWh 60 Maximum pressure at the flue gas nozzle Pa 150 150 150 150 150 Combusted gas flow minimum Kg h 91 114 138 1...

Page 17: ...13 mbar minimum m3 h 11 2 15 8 15 6 18 8 maximum m3 h 82 6 99 4 115 8 132 6 Average nitrogen oxide emission NOx mg kWh 60 Maximum pressure at the flue gas nozzle Pa 130 Combusted gas flow minimum kg h...

Page 18: ...ndensation Do not obstruct aeration grates even partially They help to reduce humidity in the home The more humid a home the more heating it consumes Turn heating off when airing a room 5 minutes a da...

Page 19: ...anufacturer s instructions in particular those relating to the regular maintenance of the unit the rules of the profession The warranty is limited to the exchange or repair of such parts as have been...

Page 20: ...dietrich heating com RU DE DIETRICH HEIZTECHNIK www dedietrich heiztechnik de AT CN Direction des Ventes France 57 rue de la Gare F 67580 MERTZWILLER 33 0 3 88 80 27 00 33 0 3 88 80 27 99 Rheiner Stra...

Reviews: