background image

B Control panel

Package MA1

   

[Basic]

       

English

03/14/08

94862242

Instructions for use, Electrical connection, Start up

 

 

Please Read & Safe This Manual for Future Reference

Summary of Contents for B control panel

Page 1: ...B Control panel Package MA1 Basic English 03 14 08 94862242 Instructions for use Electrical connection Start up Please Read Safe This Manual for Future Reference...

Page 2: ...TTINGS 4 6 USAGE 10 7 MESSAGES ALARMS 11 8 SPARE PARTS 11 CONFORMITY MARKING This product complies with the requirements of the follo wing European directives and standards 73 23 EEC Low Voltage Direc...

Page 3: ...re The safety thermostat with manual reset to make the boiler safe in operation If the boiler temperature rises abnormally 110 C 230 F the safety thermostat cuts off the burner electricity power suppl...

Page 4: ...istance greater than 3 mm Electrical connections 8575N066A GT 120 A GT 1200 A All connections are made on the terminal blocks provided for this purpose at the back of the boiler control panel The conn...

Page 5: ...7 16 o o DOMESTIC HOT WATER S ECS 19 18 o o ROOM THERMOSTAT TAM 15 14 SENSOR 3 x 1 5 mm2 mini 3 x 0 75 mm2 mini 8578N004 3 x 0 75 mm2 mini 120V 60Hz Sensor cables must be separated from cables in 120V...

Page 6: ...GT 1200 A Removable bridge Removable bridge Room thermostat Safety contact Alarm light Sensor cables must be separated from cables in 120V circuits see page 4 Minimum wire gauge 0 75mm2 18 AWG 1 5mm2...

Page 7: ...from 60 C to 90 C 140 F to 194 F factory setting 75 C 167 F 8575N070B 6 5 0 10 60 90 8575N075A 8575N075A 1 1 2 8575N054A 3 4 8575N056A The settings defined below are applicable for various functions...

Page 8: ...ac tivated heating is no longer cut off during domes tic hot water heating phases Heating pump timeout 2 4 3 3 2 1 8575N133B Switch off the boiler power supply Remove the front panel proceeding as fol...

Page 9: ...N N N N N N N N Alim 120V 60Hz L L L L TAM CH E C S S S F F 8578N006B 8578 4902B A SKELETON DIAGRAMS A HEATING PUMP LOAD PUMP CS VENT SAFETY SWTCH CONTACT DJ6A CIRCUIT BREAKER J PRINTED CIRCUIT BOARD...

Page 10: ...ker 6 A 7 Electronic thermostat Adjustment of the boiler temperature 8 Light On 6 USAGE 0 I 6A 104 122 140 158 x10 176 50 68 86 86 104 122 140 158 176 194 8578N003 1 2 3 4 5 6 7 8 9 10 For preparation...

Page 11: ...L S S0 0 Boiler sensor A AL L S S2 2 DHW sensor The corresponding sensor circuit is interrupted or is short circuited Inform the fitter See comments below Notes operating mode in case of fault A AL L...

Page 12: ...ovide the code number given in the list opposite the part reference 8578 4016A 8578N028 AD042B DE DIETRICH THERMIQUE S A S au capital de 21 686 370 Centre Pi ces de Rechange Spare Part Centre 4 rue d...

Page 13: ...6220 Red light 11 8806 5567 Basic display CPU card 12 9655 0352 WSBH 2 Harness attachment Mark Code No DESCRIPTION 13 8575 8019 Card supports GT 120 GT 1200V 14 8578 4905 Diem Easy standard GT120 har...

Page 14: ...14...

Page 15: ...15...

Page 16: ...rio N3E 1A3 CANADA Tel 519 650 0420 Fax 519 650 1709 In USA or South America 1054 North DuPage Avenue Lombard Illinois USA 60148 Tel 630 953 2374 Fax 630 953 2376 Toll Free 1 800 943 6275 www dedietri...