The safe is prepared for floor and/or wall
anchoring
Instructions Trony GTR/4P and GTR/6P
with “time delay”
High performance microprocessor.
Possible combinations: 10 billion.
Power supplied by a voltage transformer and 4 x LR6 AA
1.5-v alkaline batteries.
Alphanumeric keyboard with 12 keys: 10 keys with
numbers from 0 to 9 and 26 letters “ENTER” key to confirm
code set. The keyboard is of the membrane type with four
dedicated LEDS, and contacts for external emergency
power supply in the event of internal batteries being flat.
Internal button for programming new personal code.
DIGITS THAT CAN BE SET: minimum 4
–
maximum 10
digits in permanent memory (the “ENTER” and “ON” keys
are not valid in the combination)
Technomax
Feautures
Test for opening using the service code “1111” (with door
open and bolts pulled out): Key in the service code “1111”
and press “ENTER”. The green “OK” LED lights up for about
five seconds. Within this time, with the green LED ON, turn
the knob clockwise to retract the bolts. If the combination is
incorrect, the red “ERROR” LED will light up and the buzzer
will sound. After three attempts with incorrect codes, the
keyboard will be disabled for one minute and this time will be
indicated by the red “ERROR” LED flashing. After this time,
renewed readiness for operation will be indicated by the
green “OK” LED lighting up and a beep
Introduction
ALL SAFES ARE PROVIDED WITH SERVICE CODE “1111”
AND NO TIME DELAY. Before installing the safe, check
that it works properly and read the instructions carefully to
understand the operation. Every time a key is pressed the
green “OK” LED lights up and the buzzer sounds; pressing
the “ENTER” key causes the green “OK” LED to light up for
correct procedures, or the red “ERROR” LED to light up in
the case of incorrect settings.
Instructions for use
Connect the plug of the voltage transformer to the wall
socket and the jack to its respective socket positioned on
the right face of the safe (see pic. 3). 2. Fit the 4 x 1.5-volt
batteries (only alkaline batteries must be used) in its plastic
seating on the back of the internal lock (see Pic. 2) and
completely remove (without screwing it back on) the black
screw marked with a special yellow label, which blocks the
magnet.
Storing the personal code and set time delay
The procedure for storing the new code must be carried out
with the door open and the bolts pulled out. Press the
programming button (see Pic. 2) near the top of the back of
the door once; the button is marked with a yellow
“PROGRAMMING” label The green “CODE” LED switches on
with a steady light and stays on for 10 seconds. Within 10
seconds, start keying in your new personal code (min. 4
–
max. 10 digits) and press “ENTER”. Key in your new code set
again and press “ENTER” to confirm. If the procedure has
been carried out correctly, a long sound with a number of
tones is emitted, thus indicating that your code has been
stored. While green LED is still on, enter desired time-delay,
whit 2 digit number ex. : 00 for no delay. 20 for 20 minutes
time-delay. If errors have been made while setting your new
code, this will be indicated by the red “ERROR” LED lighting
up and a beep. Repeat the procedure for setting your new
personal code again. The code set before the incorrect
procedure will remain in memory (for new safe “1111”).
Before finally closing the safe, it is advisable to check that
everything is OK by operating the opening and closing
mechanism a number of times with the door open.