Intructions Code combi B 30
•
The enclosed inspection key allows full access to the lock
and its configurations even in case of code loss. Thus, it is at
the highest hierarchy level of the lock. Therefore, it must be
stored in a safe place, but not in the secure storage unit.
•
For security reasons programming and battery replacement
should always be performed and then tested with the
secure storage unit open.
•
Every correct key stroke recognized by the lock is confirmed
by an acoustic signal.
•
You have max. 10 sec. for each individual key stroke. If no
key is pressed during these 10 seconds, the electronics
shuts down automatically. Uncompleted operations must
be restarted after that. The only exceptions to this are the
code status query and the programming mode with 30
seconds response time until automatic shutdown.
•
Code inputs resp. all further functions (e.g. programming
operations) can be cancelled until the last key stroke by
pressing the key twice.
•
Do not use for your code personal or similar known data
which are easy to find out.
•
If the set code(s) is(are) not available, the lock can be
opened or reset using the enclosed inspection key.
•
The lock is designed for use in the temperature range from
+10° C to +50° C and with humidity of 30% to 80%
(noncondensing).
•
The lock must never be greased with or contact other
lubricants or aggressive liquids, it must be cleaned only
with a moist cloth only (no aggressive cleaning agents).
Code combi B 30
Important notes
•
Never open the lock housing. Dismount the fitting only for
battery replacement and perform it strictly according to the
specifications of these operating instructions. Avoid touching
electronic components. Otherwise, you endanger the
functions of the lock and loose the right for the warranty
claims.
•
During start
-
up the serial number of the input unit is saved
in the audit memory of the lock. Replacement of the input
unit is also registered by means of an entry in the audit
memory of the lock.
•
For every description of operation or programming
processes hereafter it is assumed that the lock and the input
unit are in the basic state. Basic state means that the lock is
closed (the bolt lock is extended) and the lock electronics is
switched off. If you are not sure, whether the lock is closed,
check if the rotary knob can be turned counterclockwise. To
ensure that the lock is not in a running programming
process, you can press the key twice to cancel it.
•
Upon delivery the lock is set by Kaba Mauer GmbH to the
assembler coder "1". For security reasons activate the
master code with your individual code immediately in order
to deactivate the assembler code. The assembler code is
meant only for lock mounting, it is not suitable for further
permanent use.
•
Furthermore, the lock has the option for partial or full start
-
up by the safe manufacturer or distributor: For a partial start
-
up basic configurations are loaded to the lock without
activation of the master code. So, the lock still opens with
"1". All configurations performed previously using software
are immediately valid only after activation of the master
code (start
-
up according to 8.2). For full start
-
up the lock has
already been provided with a master code and further
settings if necessary. In both cases the set basic configuration
is communicated separately by the safe manufacturer or
distributor. If a full start
-
up has been performed and, thus, a
master code preset as delivery code, the safe manufacturer
or distributor can save it additionally in the following
hatched text box. All pre
-
configured codes have to be
changed by the end user immediately after start
-
up.