background image

 

 

Intructions Code combi B 30 

 

• 

The enclosed inspection key allows full access to the lock 
and its configurations even in case of code loss. Thus, it is at 
the highest hierarchy level of the lock. Therefore, it must be 
stored in a safe place, but not in the secure storage unit. 

 

• 

For security reasons programming and battery replacement 
should always be performed and then tested with the 
secure storage unit open. 

 

• 

Every correct key stroke recognized by the lock is confirmed 
by an acoustic signal. 

 

• 

You have max. 10 sec. for each individual key stroke. If no 
key is pressed during these 10 seconds, the electronics 
shuts down automatically. Uncompleted operations must 
be restarted after that. The only exceptions to this are the 
code status query and the programming mode with 30 
seconds response time until automatic shutdown. 

 

• 

Code inputs resp. all further functions (e.g. programming 
operations) can be cancelled until the last key stroke by 
pressing the key twice. 

 

• 

Do not use for your code personal or similar known data 
which are easy to find out. 

 

• 

If the set code(s) is(are) not available, the lock can be 
opened or reset using the enclosed inspection key. 

 

• 

The lock is designed for use in the temperature range from 
+10° C to +50° C and with humidity of 30% to 80% 
(noncondensing). 

 

• 

The lock must never be greased with or contact other 
lubricants or aggressive liquids, it must be cleaned only 
with a moist cloth only (no aggressive cleaning agents). 

 

Code combi B 30

 

 

Important notes

 

 

• 

Never open the lock housing. Dismount the fitting only for 

battery replacement and perform it strictly according to the 
specifications of these operating instructions. Avoid touching 
electronic components. Otherwise, you endanger the 
functions of the lock and loose the right for the warranty 
claims. 

 

• 

During start

-

up the serial number of the input unit is saved 

in the audit memory of the lock. Replacement of the input 
unit is also registered by means of an entry in the audit 
memory of the lock. 

 

• 

For every description of operation or programming 

processes hereafter it is assumed that the lock and the input 
unit are in the basic state. Basic state means that the lock is 
closed (the bolt lock is extended) and the lock electronics is 
switched off. If you are not sure, whether the lock is closed, 
check if the rotary knob can be turned counterclockwise. To 
ensure that the lock is not in a running programming 
process, you can press the key twice to cancel it. 

 

• 

Upon delivery the lock is set by Kaba Mauer GmbH to the 

assembler coder "1". For security reasons activate the 
master code with your individual code immediately in order 
to deactivate the assembler code. The assembler code is 
meant only for lock mounting, it is not suitable for further 
permanent use. 

 

• 

Furthermore, the lock has the option for partial or full start

-

up by the safe manufacturer or distributor: For a partial start

-

up basic configurations are loaded to the lock without 

activation of the master code. So, the lock still opens with 
"1". All configurations performed previously using software 
are immediately valid only after activation of the master 
code (start

-

up according to 8.2). For full start

-

up the lock has 

already been provided with a master code and further 
settings if necessary. In both cases the set basic configuration 
is communicated separately by the safe manufacturer or 
distributor. If a full start

-

up has been performed and, thus, a 

master code preset as delivery code, the safe manufacturer 
or distributor can save it additionally in the following 
hatched text box. All pre

-

configured codes have to be 

changed by the end user immediately after start

-

up. 

 

 

 

Summary of Contents for Code combi B 30

Page 1: ...ctions of the lock and loose the right for the warranty claims During start up the serial number of the input unit is saved in the audit memory of the lock Replacement of the input unit is also registered by means of an entry in the audit memory of the lock For every description of operation or programming processes hereafter it is assumed that the lock and the input unit are in the basic state Ba...

Page 2: ... intruder EMA Intruder detection system external alarm system for evaluation forwarding of the duress alarm or secured permanent power supply not included in the scope of delivery Undervoltage indication indicates that the batteries are low and must be replaced as soon as possible in order to ensure secure function of the lock AHK Take off contact A contact in the input unit which detects whether ...

Page 3: ...th 00 xxxxxx and press the arrow Then check the performed programming with the storage unit still open To do so proceed according to chapter 10 1 NOTE If the Incorrect code signal is output the procedure must be repeated since both codes do not match or the ID here 00 has been entered incorrectly Changing of the master code can be canceled any time by pressing twice Alternatively the process can b...

Page 4: ...ribes the basic programming procedures for further codes user or courier codes This includes activation deletion blocking and releasing of these codes The basic code structure is given in chapter 5 authorizations Furthermore this chapter describes the code status query used by the master co de to request the status of individual codes directly from the lock For correct use of the lock the master c...

Page 5: ...hat the silent alarm is activated and the alarm codes can be used Description 1 Press P and enter the valid master code and arrow Press P8 and arrow NOTE The silent alarm must be deactivated in order to be able to activate it If the red LED is displayed additionally to the normal acknowledgment signal the silent alarm has been activated previ ously and is deactivated now To activate it again repea...

Page 6: ...ion key The OD can be avoided if the inspec tion key is used but it cannot be deleted Opening with silent alarm Description 1 Enter the first valid opening code and arrow ID 00 to 30 or 95 X programmed 6 digit combination for the corresp ID num ber 2 Now the signal for the input of the second is displayed 1x Led green 2 s break 3 Enter another valid opening code and arrow ID 00 to 30 or 95 however...

Page 7: ...tandby times have been programmed they can be overridden here c Double code override This function turns the programmed double code into a simple code The second code which is requi red usually is omitted here d Omission alarm If this function is activated at the lock an se parate input signal must be initiated max 60 seconds before the code input e g by means of a hidden button otherwise the lock...

Page 8: ...ly recommended to use high quality brand batteries and replace them as a precauti on every 24 months at the latest After the battery replacement mount the input unit on the base part from the front in the or der reverse to the one described above and move it laterally until it engages and the red LED turns off Then attach the screw to secure the top part Now attach the rotary handle in the posi ti...

Reviews: