Purpose
Required
Interval
Procedure
5.6.14 Clean brewer with cleaning tablet
NOTE
Failure to clean the brewer with the recommended cleaning
tablet, available from the manufacturer, will void the warranty
on related parts. Not cleaning the brewer can cause the machine
to malfunction! Our advice is to do this at least once a week.
Cleaning of the brewer with a cleaning tablet removes all coffee
residue. The brewer remains in the coffee machine.
Use the following parts to perform the procedure:
• Cleaning tablet.
• Rinsing tub or 1 liter jug.
• Protective clothing, gloves and safety glasses.
• Green service key.
Perform this procedure:
• At least once a week, increase the frequency if needed.
NOTES
• Total time for the cleaning cycle is 8 minutes.
• A message is shown if the brewer is
not
cleaned
after 7 days.
• A message is shown and coffee dispense is
disabled
if the brewer is not cleaned after 9 days.
Perform the following steps:
1.
(on page 45).
2. In the
Service
menu tap the
[Brewer Cleaning Cycle]
button.
A first submenu (step 1) is shown.
▪
Follow the
Brewer Cleaning Cycle
instruction shown on-
screen and described in the next steps.
3. Place the service key.
Virtu XNA Small Cabinet 180 CoEx XL® brewer User Manual 5DUXNK20M EN V2.1
68