background image

     

 

  5 / 9 

 

WWW.DDTOP.COM 

 

1. Transmission Mechanism 

2. Tensioning Mechanism 

3. Guide Wire Rope 

4. Ruler 

5. Heavy Hammer 

6. Transmission Wire Rope 

7. Buoy 

8. Guiding Mechanism 

2.2 Operating Principle 

The UFZ-4A buoy level gauge is designed according to the principle of force balance. The working 
principle is shown in Figure 1. Let the weight of the float be W, the buoyancy of the float be F, the 
weight  of  the  pointer  weight  be  G,  and  the  friction  of  the  whole  system  be  f.  When  the  float  is 
immersed in a position in the liquid, these forces are in equilibrium.  W-F-G±f=0. When the level 
changes, it causes the change of the position of the float. The pointer hammer is moved by the wire 
rope, and the corresponding position of the level is displayed on the scale to achieve the purpose of 
level measurement. 

2.3 Packing 

Please send the packaging waste to a special recycling agency. 

2.4 Transporting 

When hoisting and transporting, please select qualified hoisting equipment and lifting straps, and 
pay attention to safety. 

2.5 Warehousing 

Storage Temperature -20℃~40℃; Storage Humidity≤40%. 

3.

 

Technical Characteristics 

3.1 Main Performance 

3.1.1 Product implementation standards:Q/AMM005-2010   

3.2 Main Performance 

3.2.1 Medium density:≥0.6g/cm3 
3.2.2 On-site indication accuracy: ±20mm 

 

 

Summary of Contents for UFZ-4A

Page 1: ...1 9 WWW DDTOP COM UFZ BUOY LEVEL GAUGE UFZ Operation Manual UFZ DT JS 1011 2018 A...

Page 2: ...t prior notice Quality Assurance Dandong Top Electronics Instrument Group Co Ltd guarantees that all glass plate level gauge have no defects in materials and manufacturing processes within one year fr...

Page 3: ...2 Operating Principle 5 2 3 Packing 5 2 4 2 4 Transporting 5 2 5 Warehousing 5 3 Technical Characteristics 5 3 1 Main Performance 5 3 2 Main Performance 5 4 Dimensional Schematic Figure 2 6 5 Unpackin...

Page 4: ...sure to install the equipment in Intrinsically safe or non flammable site operating procedures 1 2 Process Leaks Can Cause Serious Injury or Death Care should be taken to lift the transmitter If the...

Page 5: ...e in equilibrium W F G f 0 When the level changes it causes the change of the position of the float The pointer hammer is moved by the wire rope and the corresponding position of the level is displaye...

Page 6: ...d Inspection 5 1 Unpacking Inspection Notice 5 1 1 Check whether the product nameplate Figure 3 is consistent with the supply list information Figure3 Sample Nameplate 5 1 2 Check the quantity of each...

Page 7: ...the fixing bracket of the welding scale should be placed on a vertical line with a deviation of 2 Figure 4 Figure 4 Installation 6 2 2 The bottom guiding mechanism and the buoy are taken into the tan...

Page 8: ...oy are taken into the tank from the inlet hole By observing the perpendicularity of the guide wire at the top it is determined that 2 and the bottom guiding mechanism is welded and fixed to the bottom...

Page 9: ...be paid to hazardous process conditions such as pressure inside the vessel high temperatures corrosive or toxic media etc 8 2 Waste Removal Waste disposal should be carried out in accordance with the...

Reviews: