dCS Paganini Upsampler
User Manual
Software Issue 1.1x
March 2011
Filename: Paganini Upsampler Manual v1_1x.docx
Page 15
English
version
F
RONT
P
ANEL
Figure 6 – Front panel
POWER
Button
To switch on, ensure the rear panel switch is set to
I
and press the
POWER
button (A) on the front
panel once. Note that the unit cannot be turned on from the remote control.
To set the unit to sleep mode, press the
POWER
button once. The main display will turn off, the LED
to the left of the button will illuminate, and the outputs will mute, but the unit will remain close to
running temperature. Press again to return to normal operation.
To switch off, hold down the
POWER
button for about 5 seconds until
Power Down
appears on the
display, then release it.
When the menu is open, press the
POWER
button to close the menu.
MENU
Button
Press the
MENU
button (B) to open the menu, select menu pages and change settings. See the Menu
section on page
for information on using the menu features.
INPUT
button
Press the
INPUT
button (E) repeatedly to cycle through the available digital inputs. The sequence is:
AES
,
USB
,
RCA1
,
RCA2
,
AES
, etc.
When the menu is open, the
INPUT
button changes to the
<
button, used to page backwards through
the menu.
OUTPUT
Button
Use the
OUTPUT
button (F) to select the output sample rate / format. The sequence is:
32kS/s
,
44.1kS/s
,
48kS/s
,
88.2kS/s
,
96kS/s
,
176.4kS/s
,
192kS/s
,
DSD
,
32kS/s
, etc.
The output rate cannot be less than the input rate, so the lower rates may disappear from the list.
Once the output rate is set, it is not affected by a change of digital input or input sample rate, unless
the input rate exceeds the output rate. If this should happen, the output changes to match the input
rate.