SBC

 

NiMH Battery Charging System 

 

 

Overview 

The DCI NiMH battery charger (SBC) system includes an 
AC power cord, a power unit attached to the battery 
charger, and rechargeable DCI NiMH battery packs. The 
battery packs power a DigiTrak receiver and remote 
display. 

The battery charger operates from an AC power (100

240 V, 50

–60 Hz, 0.35 A max.). The AC power cord 

shipped with your system is standard to your region. 
Batteries are sold separately. 

A battery will take approximately three hours to recharge. 
If power to the charger is interrupted while charging a 
battery, the charger will reset and start a new charge cycle 
when power returns. The DCI NiMH battery pack should 
be fully charged and fully discharged twice to establish 
optimum battery performance. 

This battery charger is only designed for indoor use and 
should not come into contact with water or dust. To avoid 
overheating, do not cover the charger while in use. 

 

Only DCI NiMH battery packs can be charged in the 
SBC charger; trying to charge any other type of battery 
could result in damage and voiding of the warranty. 

 

Although a DigiTrak receiver and remote display can 
accept a DCI lithium-ion battery pack, you 

cannot

 

charge a lithium-ion battery pack in the SBC charger. 

 

Setup 

Connect the 

AC power cord

 into the 

power unit

, then 

plug the cord into an AC power receptacle. Wait until the 
LED on the power unit changes to orange before inserting 
a battery for charging. 

Charging 

With the battery charger is connected to a power source 
and the LED illuminates orange, insert a battery pack into 
the charger. The battery pack will be flush with the battery 
charger when it is properly inserted. Do not charge a non-
DCI battery pack or a DCI lithium-ion battery pack with this 
charger.  

The LED will remain orange while the battery is initialized 
in the charger. When charging begins, the LED will 
change to red. During the final stage of charging, the LED 
will change to green, at which point the battery has 
completed charging. If the battery remains in the charger, 
the LED will flash orange while the battery is topped off. 
DCI recommends removing the battery from the charger 
within 24 hours.  

After plugging in the charger or removing a battery, wait 
approximately 15 seconds before inserting another battery 
pack. The battery charger is ready to charge a battery 
when the LED turns orange. 

If the battery does not reach full charge within 4 hours, the 
charger will automatically go into trickle charge mode to 
ensure the battery does not overheat. 