DCG GH06_G Instruction Manual Download Page 1

GH06_G 

STUFA A GAS 

 GAS HEATER

dcg16.it

CLIMA

MANUALE D’ISTRUZIONI - INSTRUCTION MANUAL

Summary of Contents for GH06_G

Page 1: ...GH06_G STUFA A GAS GAS HEATER dcg16 it CLIMA MANUALE D ISTRUZIONI INSTRUCTION MANUAL...

Page 2: ...NUALE ONDE EVITARE PERICOLO DI INCENDIO O ESPLOSIONE CON CONSEGUENTI DANNI A COSE O PERSONE O MORTE CARATTERISTICHE TECNICHE Tipologia Stufa mobile a infrarossi per ambienti dotata di sistema di rilev...

Page 3: ...sione di 0 6 mm PRECAUZIONI DI SICUREZZA 1 Usare sempre la stufa seguendo le istruzioni contenute nel manuale che deve essere conservato in un luogo sicuro 3 NON posizionare la stufa vicino a mobili 4...

Page 4: ...erdita NON scollegare il regolatore Interrompere l alimentazione di gas in corrispondenza della bombola o del regolatore Portare la stufa all aperto in un luogo in cui non siano presenti fiamme Accend...

Page 5: ...necessario garantire un adeguata ventilazione negli ambienti in cui viene usata in mododa disperdere i prodotti della combustione e garantire il ricambio d aria Un adeguata ventilazione dovrebbe ridu...

Page 6: ...sempre usando il regolatore 9 Quando la stufa viene accesa per la prima volta o dopo un certo periodo dall ultimo utilizzo posizionarla all aperto e lasciarla in funzione per 15 minuti 10 Non usare la...

Page 7: ...ere conforme allo standard EN 1763 1 Classe 3 La manichetta utilizzata deve essere conforme alle normative vigenti nel Paese di utilizzo La lunghezza deve essere al massimo di 0 5 m Se la manichetta c...

Page 8: ...oppia e la valvola siano collegate correttamente 3 Controllare la termocoppia 4 Controllare la valvola elettromagnetica 4 Dopo aver selezionato la posizione massima con tutti e tre i pannelli accesi l...

Page 9: ...collegare il regolatore al tubo flessibile e alla valvola 3 Aprire la bombola e il regolatore 4 Se il regolatore non in dotazione o manca rivolgersi al fornitore di gas in modo da ottenere il tipo co...

Page 10: ...ntilato Rivolgersi al fornitore per ricevere assistenza NON USARE LA STUFA Dopo aver effettuato il test fissare la copertura posteriore SOSTITUIRE LA BOMBOLA 1 Prima di rimuovere e sostituire la bombo...

Page 11: ...s 2 Pos 3 Premere e ruotare la manopola sul simbolo e tenerla premuta per 10 secondi Mentre si tiene premuta la manopola premere l interruttore finch la fiamma pilota nella parte inferiore del bruciat...

Page 12: ...tenere premuto l interruttore per pi di 40 secondi 3 Non scollegare il regolatore mentre la valvola della bombola o il regolatore sono aperti 4 Non sostituire la bombola in ambienti in cui sono prese...

Page 13: ...parti deve essere rimossa definitivamente NON GARANTISCE COMPLETA PROTEZIONE PER BAMBINI PICCOLI O PERSONE INVALIDE 18 Non spostare la stufa mentre in funzione Urti e colpi potrebbero attivare il dis...

Page 14: ...lungo periodo l utente tenuto a controllare che funzioni correttamente verificando ad esempio se il tubo flessibile e il regolatore sono ancora validi se il collegamento tra la bombola di gas e la st...

Page 15: ...HONGSHAN ELECTRICAL APPLIANCE CO LTD TECHNICAL CHARACTERISTICS Type Infrared Space Heater mobile equipped with Atmosphere sensing system and flame failure Device Dimensions 40 40 720 D W H Category I...

Page 16: ...ance with instructions supplied with each heater Keep instructions in a safe place 3 DO NOT position heater close furniture 4 DO NOT move heater from room to room when lit 2 DO NOT place clothes or ot...

Page 17: ...be positioned on a level surface at all times 6 If a leak is suspected DO NOT disconnect the regulator Turn off the gas supply at the gas bottle or gas regulator Take the appliance outdoors in a flam...

Page 18: ...For this reason adequate ventilation should be provided in rooms in which the heater is used This ensures the removal of products of combustion and allows the entry of replacement air Adequate ventil...

Page 19: ...t use light the heater outside and burn outdoors for 15 minutes 10 Do not use your heater while sleeping 11 Do not use your heater in high rise flats 12 Do not use your heater in basements bathrooms o...

Page 20: ...andard of EN1763 1 Class 3 The hose used must conform to the relevant standard for the country of use The length of the hose must be 0 5m maximum Worn or damaged hose must be replaced Ensure that the...

Page 21: ...me b Ensure good connection between thermocouple and valve c Check thermocouple d Check electromagnetic valve 4 After changing to maximum position with all three plaques alight one or more plaques app...

Page 22: ...e regulator to flexible tubing and the valve 3 Turn the cylinder and the regulator on 4 Where the regulator is not supplied or is missing please contact your gas dealer to advise of the correct type f...

Page 23: ...ted area Contact your gas supplier for assistance DO NOT USE THE HEATER Fix the rear cover after leakage test HOW TO CHANGE A CYLINDER 1 Turn off at the regulator and allow the heater to cool fully be...

Page 24: ...5 seconds more Release the button if the pilot flame goes out repeat the above operation 3 HEAT SETTINGS To change from minimum to maximum gently press control button and turn it position 3 To change...

Page 25: ...utlets 11 Do not use the heater in bathrooms showers of swimming pool leisure vehicles such as caravans or auto caravans 12 This heater must not be used without a gas cylinder fitted for stability pur...

Page 26: ...gets onto the burners or pilot light area Wipe the heater completely dry before use 3 Don t use abrasive cleaners as they may damage the quality of paint finish MAINTENANCE 1 Check flexible tubing be...

Page 27: ...the gas cylinder connect the regulator to flexible tubing and the valve 8 Turn the cylinder and the regulator on 9 Where the regulator is not supplied or is missing please contact your gas dealer to a...

Page 28: ...ifferenziati a seconda dei rifiuti elet tronici ed elettrotecnici oppure riconsegnarla al rivenditore al mo mento dell acquisto di nuova apparecchiatura di tipo equivalente in ragione di uno a uno opp...

Page 29: ...allaggio originale unitamente allo scontrino La riparazione e o la sostituzione di pezzi soggetti a logoramento come anche operazioni di pulizia e manutenzione non rientrano nella garanzia e quindi so...

Reviews: