background image

 

DBK Issue 1 

11/06/2014   

IS001 

“Blizzard Series” Convection Heater User Instructions

 

 

 

Product Description 

 
DBK Blizzard heater series are a range of convection heaters incorporating self limiting heater 
technology for energy efficient and accurate climate control inside equipment enclosures. 
 
All products in this range are IP20. 
All products in this range are protection class II 
Operating voltage is 100 - 240 V  
All powers measured at 10°C ambient temperature 

 

Application 

 

For use inside equipment enclosures to prevent condensation 
and provide climatic control.  

 

For use inside Industrial cabinets to prevent condensation and 
provide climatic control.  

 
 

 
 
 

Installation 

 

Installation by trained personnel only 

 

Mount the heater by attached DIN rail clip 

 

This is a high performance heater. Please leave horizontal and vertical clearance H / V = 20 / 
50mm for heater type “L”, and H / V = 20 / 500mm for heater type “H” for optimized natural 
convection and avoid placing directly below heat sensitive components. 

 

Check the labelling of the heater before connecting to the power supply and take care to satisfy 
laws and regulations 

 

Do not allow electrical wires to come into contact with the body of the heater or directly in front of 
the hot air outlet.  

 

Do not mount the heater near any flammable materials. 

 

A means for disconnection must be provided in the fixed wiring of the system. This must have a 
contact separation of at least 3mm in all poles, and shall be incorporated in accordance with wiring 
regulations. 

 

This equipment should be protected by a Ti

me delay “T” fuse to avoid false tripping due  

       to cold starting. 

 
Operation 

Connect Europa terminal block to live and neutral. 
 

Heater Type 

Power 

(measured at 10°C) 

Suggested fuse rating (time delay) 

110 V / 240 V

 

Blizzard 50L 20W 

20 W 

2 A 

Blizzard 200L 30W 

30 W 

4 A 

Blizzard 50H 40W 

40 W 

4 A 

Blizzard 200 H 65W 

65 W 

6 A 

 
Power at U<140V is ~10% reduced. 
 
Maintenance 

There are no user serviceable parts inside this unit.  Disassembly should not be attempted. 
 

Warnings 

 

Never work on live equipment. 

 

Do not touch the heater during operation, as it will be HOT. 

 

The heater will remain hot for several minutes after switch-off; let the heater cool down before 
removing or touching.  

 

Do not remove any attached adhesive labels. 

           
 
 
 
 
 
 
 
 