31
DVA KS10
Code 420120233 REV. 1.0
English
ATTENTION
!
SECOND DVA KS10 MODULE
CONNECTING AND POTENTIAL LINKING OF POWER SUPPLY BETWEEN 2 SUBS
FIRST DVA KS10 MODULE
LINK
•
Connect the first module power supply to AUTO-RANGE MAINS INPUT (10). For this
purpose, use a cable equipped with a powerCON connector (not included in the supply).
•
Extend the power supply from the first to the second module, by connecting the MAINS
LINK OUTPUT (11) to the AUTO-RANGE MAINS INPUT (2), as shown in the figure.
• Repeat the operation between the second and the third modules, and so on, until all line-
array modules are connected (check the maximum number of power supply extensions).
•
The amplifier nameplate of the DVA KS10 module specifies the
maximum and total current (and power) value of a multiple module
system with extension connections.
•
The cables must be properly sized; design, installation and testing
of the system should be performed only by qualified personnel. AEB
Industriale accepts no responsibility in the event of use of cables
which are unsuitable, uncertified or incompatible with the proper
system sizing or with the regulations in force in the country of use.
POWER SUPPLY