The owner of the machine (customer) must ensure that it is always used in perfect condition. In this

 

   

 

 

 

 

 

     

 

   

 

   

 

regard, always keep the device clean and periodically perform visual checks on the outside of the

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

device, on the power cord and on the charging plug, looking for any damage or residual dirt. 

If the column is damaged ,it must be immediately disconnected and replaced. 

The charging station should only be used to charge electric vehicles and plug-in hybrids. Do not

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

connect with other electrical devices. 

The product does not have its own grid switch. The disconnection from the electric grid takes place

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

through the device connector and the magnetothermal switch of the building system. 

Do not use extension cords to connect the device to the electric grid. 

Make sure that the power supply cable of the wallbox is not damaged mechanically (by bending or

 

 

 

 

 

 

   

 

   

 

 

 

 

   

crushing it with the vehicle). After use, place the plug in the connector holder. 

Be careful not to damage the charging station. 

Daze Technology srl assumes no responsibility for any damage to the body of the product due to

 

 

 

 

 

 

 

 

   

 

   

 

 

   

accidents. 

The use of the machine in an explosive atmosphere is not permitted.  

The modification of parts of the components or the addition of optional equipment to the device is not

 

   

   

 

   

 

   

 

   

 

   

 

permitted. 

Do not remove any labels such as safety symbols, cable codes or nameplates. 

During operation, the device cannot be exposed to direct radiation such as sunlight, as these can

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

produce overheating of the internal environment, where the electrical equipment is located, degrading

 

   

 

 

 

 

 

 

   

 

 

the insulating materials. 

The degree of protection of the machine is IP54; that is, the environment of use must be clean, in the

 

   

   

 

   

 

   

 

   

 

 

 

   

 

absence of dust or vapors. 

 
 

1.4. Warranty 

Daze Technology srl guarantees the regular operation of the machine (as long as it is used in the conditions

 

 

 

 

 

 

   

 

 

 

       

   

 

 

of intended use) for the period established in agreement with the DazeTechnology srl Sales Office and

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

regularly registered in the sales contract. 
Daze Technology srl guarantees all its machines from factory defects for a period of 24 months starting

 

 

 

 

 

 

 

 

 

 

   

   

 

 

 

from the delivery date. This guarantee consists in restoring efficiency, through free replacement or repair,

 

 

 

 

 

 

   

 

 

 

 

   

 

of items that are unusable or inefficient due to factory defects and / or assembly errors. This warranty is

 

 

 

 

   

 

   

 

 

     

 

 

 

   

void if the defect can be connected with: 

Failure to perform the minimum maintenance interventions prescribed in the manuals. 

Carelessness. 

Accidents. 

Late complaint of the defect. 

Improper use. 

Unauthorized modification. 

Repair with non-original spare parts. 

For each component sent to Daze Technology srl for inspection, repair or replacement, whether to be

 

 

 

   

 

 

 

 

 

   

 

   

 

performed free of charge or against payment if the warranty period has expired, the Customer must

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

compulsorily complete a document with the identification data of the machine and the largest number of

 

   

 

 

 

 

   

 

 

 

 

 

   

information relating to the fault. This will improve the "Customer Service" and minimize the costs and time

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

required for the revision or replacement of defective parts. 
We emphasize that if we do not receive the defective part, no later than 30 days from the shipping date of

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

the new spare part, we will automatically proceed with billing. 

 

ENG - June 2020 - Rev. 1 

Summary of Contents for DazeBox

Page 1: ...DazeBox V5 1 Installation use and maintenance manual 1 ENG June 2020 Rev 1...

Page 2: ...atures 5 3 Use 8 3 1 Intended use 8 3 2 Unintended use 8 4 Installation 9 4 1 Supply 9 4 2 Transport and storage 9 4 3 Preliminary checks 10 4 4 General Criteria for selecting the place of installatio...

Page 3: ...in compliance with current safety regulations Therefore the product does not normally entail any danger to people or things The machine and its components are designed in such a way that they cannot...

Page 4: ...electrical equipment is located degrading the insulating materials The degree of protection of the machine is IP54 that is the environment of use must be clean in the absence of dust or vapors 1 4 War...

Page 5: ...of safety and also for its ability to deliver high currents The control circuit also provides for the communication between the charging station and the vehicle through the PWM Pulse Width Modulation...

Page 6: ...Figure 1 DazeBox charging station and its external components Figure 2 Dimensions of the DazeBox charging station 6 ENG June 2020 Rev 1...

Page 7: ...re range at 32 A from 25 C to 45 C without direct exposure to sunlight Protection degree IP54 There are three types of DazeBox for three different recharging powers in accordance with customer needs M...

Page 8: ...stand by awaiting charging The status of the LEDs is pulsed green To charge the vehicle pull out the charging cable by always holding it by the plug and never by the cable itself and connect it to th...

Page 9: ...ait for the charging cycle to be completed and for the vehicle to be disconnected before opening the device 4 1 Supply Inside the packaging is supplied DazeBox with Type 2 cable of 3 or 5 meters The 5...

Page 10: ...nstall the device in places at risk of explosion EX environment used as escape routes where objects can fall eg hanging stairs or car tires in which it is possible that it is hit by jets of water unde...

Page 11: ...nting on the wall with relative dimensions of the DazeBox with 3 meter cable For Dazebox with 5 meter cable and cable holder refer to figure 5 Figure 5 Depiction of mounting on the wall with relative...

Page 12: ...r edge of the plate figure 4 for the 3 meter cable version 1200 1500 mm with respect to the lower edge of the plate figure 5 for the 5 meter cable version Mark the three holes using a drilling templat...

Page 13: ...current chosen must be suitable for the circuit breaker and the fuse The earth connection is ensured by the user s system The device does not have its own electric grid switch The differential switch...

Page 14: ...agement system setting The installation of power management involves connecting the current transformer to the electric meter In order to complete the installation a 0 5 mm shielded bipolar cable must...

Page 15: ...erly stripped and that the shielding is well in contact with the earth terminal Figure 10 Power management wiring Once the electrical connection is complete the current can be adjusted Using the curre...

Page 16: ...onnection wires to the appropriate length The wires must be as short as possible 2 Remove approximately 12 mm of insulation from the connection wires For thin connection wires it is recommended to use...

Page 17: ...rt 2 The measuring instruments used must comply with national regulations eg DIN EN 60557 VDE 0413 Electrical safety in low voltage grids up to AC 1000V and DC 1500V 3 Measurement results must be docu...

Page 18: ...absence of national regulations manufacturers recommend checking each month Acting on the test button the device must intervene immediately Otherwise contact your trusted technician because the safet...

Page 19: ...ror state Each error is associated with a corresponding number of short consecutive flashes In case of error contact support Numero lampeggi Errore 2 Temperature to high 5 Error on vehicle side 6 Gene...

Page 20: ...nce with the regulations in force in the country of use Decommissioning and disposal of the product When the equipment is disposed of all components and materials must be identified and separated to a...

Page 21: ...Registered office Via per Curnasco 24127 Bergamo Italy Headquarters Via Aldo Moro 2c 24030 Almenno San Bartolomeo BG Italy Mail head dazetechnology com Tel 39 035 1983 1355 Website www dazetechnology...

Reviews: