Days BE05W Assembly And Operating Manual Download Page 1

B AT H   S E AT

B a t h

6HDW

ASSEMBLY and
OPERATING MANUAL

Doc.-No.: E1-04-043-001

BE05W and BE06W

Summary of Contents for BE05W

Page 1: ...BATH SEAT Bath 6HDW ASSEMBLY and OPERATING MANUAL Doc No E1 04 043 001 BE05W and BE06W...

Page 2: ......

Page 3: ...ou have any other questions about this bath seat please contact your supplier Introduction Contents 1 0 Safety instructions 4 1 1 Symbols used 4 1 2 Use in accordance with the requirements 4 1 3 Safet...

Page 4: ...t Considerably reduced function lacking function of the lower extremities e g amputation paralysis joint disease while upper body control and capacity of the upper extremities is still sufficient The...

Page 5: ...e gases or vapours e g from anaesthetics can be expected Make sure before use that the bath seat rests securely on the rim of the bath tub Safety information 1 3 Safety General notes Please read the a...

Page 6: ...e the following list to check the contents of the package before starting the assembly Please contact Days Healthcare or your medical supply shop if defects are apparent or if parts are missing Extent...

Page 7: ...e rubber caps Assembly 3 0 Assembly Observe the safety notes in chapter 1 3 3 1 Preparations Prepare all fastening screws as follows 6 Allen screw with 7 plastic disk Prepare fastening screws 3 2 Asse...

Page 8: ...r with deep turned groove 3 onto the upper fastening screw and screw down backrest 4 Push washer with deep turned groove 5 onto the upper fastening screws NOTE For easier assembly first screw in all f...

Page 9: ...wn seat frame 8 Screw the side panel to the seat frame and the backrest NOTE Tightening too much results in the destruction of the threaded inserts Tighten all six fastening screws Press all masking c...

Page 10: ...ath seat rests securely on the bath tub rim Only use the bath seat in bath tubs for which the secure support of the rubber caps 1 is guaranteed At least 2 3 of the width B of all four rubber caps 1 ha...

Page 11: ...oved by non scouring mild cleaning agents 5 2 Disinfection If disinfection is required during use only agents according to the Days Healthcare skin protection and hygiene plan must be used Carry out t...

Page 12: ...be carried out according to the regional environmental and disposal provisions 10 0 Specifications Days Healthcare offers a 24 months warranty on perfect quality within the framework of its general te...

Page 13: ......

Page 14: ...rs Stamp Days Healthcare A Trading Division of Patterson Medical Ltd North Road Bridgend Ind Est Bridgend UK CF31 3TP Tel 01656 664700 Fax 01656 664750 E Mail info dayshealthcare com www dayshealthcar...