12 

 

 

By pressing 

 button power or water consumption per/min can be displayed.  

When you turn on hot water tap water device will be operated and 

 symbol 

will be seen at the display.   

In case of water quantity passing inside the device exceeds maximum value, 

 symbol will be seen. In this case, reduce water flow quantity by cut 

down water heater inlet valve.   

 

 

 

 

For short term period, turn off device by pressing 

 button. In this way, 

freezing  prevention  system  will  be  active  (by  leaving  electric  power 

supply active) 

 

If  you  will  not  operate  the  device  for  a  long  time,  after  pressing   

 

button. Because of freezing prevemtion will not operate, discharge the 

wayet inside system in case of freezing.  

 

 

 

 

 

 

 

 

 

 

   5.3. Turn Off Device  

   5.3.1. Temporary Off 

   5.3.2. Long Term Off 

Summary of Contents for UKDAX-10KSM

Page 1: ...1 ...

Page 2: ...ate the device by yourself 3 Water installation connection of the device must be done as leakproof and durable 4 The device operates with voltage determined inside this manual according to its model Suitable system voltage must be provided 5 When it is supplied electric distribution from any electric resource like generator except city electric network must be sure that necessary conditions are pr...

Page 3: ... immediately informed 14 If the device will not have used for a long time performing following points are suggested Bring switch of the device OFF position Close water inlet pipe of device Discharge tap hot water cycle for preventing freezing 15 Device cannot be used by children or disabled people without helper 16 In case of having smoked or burning smell originating from device make switch of th...

Page 4: ...380 V 50 Hz UKDAX 10KST 10 410 270 106 5 4 5 8 UKDAX 12KST 12 5 4 6 9 UKDAX 16KST 16 6 7 9 2 UKDAX 18KST 18 8 2 10 4 UKDAX 20KST 20 8 2 11 5 UKDAX 24KST 24 8 2 13 8 1 220 V 50 Hz UKDAX 10KSM 10 410 270 106 5 4 5 8 UKDAX 12KSM 12 5 4 6 9 UKDAX 16KSM 16 6 7 9 2 General Technical Specifications Min Operation Pressure bar 0 3 Max Operation Pressure bar 6 Min Setting Temperature o C 35 Max Setting Temp...

Page 5: ...er For the correct positioning of device Installation must not be done on the cooker or similar cooking devices Do not leave combustion products inside device installed room 4 WATER INSTALLATION 4 1 Installation Conditions and Safety Warnings Installation of water heater must be done by authorized personnel ...

Page 6: ... water pressure does not exceed 6 bar If you suspect have pressure reduction installed Device installation place must be far way from blockers obstruction parts and bulges during repairing and maintenance There must be sufficient space around the device for maintenance and repair Electric connection of the device must be made with suitable cable fuse and residual current device and grounding absol...

Page 7: ...7 ...

Page 8: ...rom top to bottom to screws that you fasten the heater Make sure that screw head is fix to hole of installation part and will not remove Water installation connections must be done with flexible joint as leakage proof Cutoff valve must be placed to device inlet before flexible connector 4 2 Wall Installation Of Water Heater 4 2 1 Connection Of Water Installation Excessive tight cable connections m...

Page 9: ...e must be located near the device there must be cable after fuse which is enough as making connection to device Connection of cables to device must be made by authorized personnel Water heater capacity and cable sections which are calculated cable length residual current device and fuse ampere values can be seen at following table Model Phase Voltage V Power kW Drawn Current A Fuse and Residual Cu...

Page 10: ...heater Water flow indicator Device operation indicator Temperature setting value Device operation temperature Avarage power and water flow indicator ON OFF button Power waterflow selection button Temperature increasing button Temperature decreasing button High Water Quantity Warning 5 OPERATION OF WATER HEATER AND USAGE 5 1 Display And Knobs ...

Page 11: ...lip screw as not loose Make sure that cable is fix complete and solidly Complete connection by appliying same processes for another cables For notr connection suitable measurement connector must be used Open residual current device and fuse Press button for TURN ON the device Display will be as in the following By pressing or buttons temperature can be increased or decreased 5 2 Operation Od Devic...

Page 12: ...een In this case reduce water flow quantity by cut down water heater inlet valve For short term period turn off device by pressing button In this way freezing prevention system will be active by leaving electric power supply active If you will not operate the device for a long time after pressing button Because of freezing prevemtion will not operate discharge the wayet inside system in case of fr...

Page 13: ...13 6 ELECTRICAL DIAGRAM ...

Page 14: ...erials and production When you meet with problem while using please contact with our after sales service department Repairing and maintenance of the device by unauthorizedperson will make the device out of warranty Afterwards our company will not responsible from damages and accidents 7 REPAIR AND SERVICE ...

Page 15: ...ot Low voltage Control device voltage Fan failure For three phase devices Control device phases High water temperature Setting temperature is high Control device temperature setting Electrical failure Call authorized service Device display lights not ON Device is in standby position When water flow starts device automatically operates Device is OFF position Control if device is ON or not No energy...

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...l Mah Marmara Cad No 74 Ümraniye İstanbul Tel 90 216 369 85 36 37 Fax 90 216 385 95 45 E Mail info daxom com Yetkili Servisler www daxom com Merkez Servis Namık Kemal Mah Marmara Cad No 74 Ümraniye İstanbul Tel 90 216 360 71 21 22 Fax 90 216 360 72 25 ...

Reviews: