daviteq WS433-CO2 User Manual Download Page 1

WS433-CO2-MN-EN-01  

JUN-2021

SKU

WS433-CO2

HW Ver.

2.5

FW Ver.

5.0

Item Code

WS433-CO2-01

WIRELESS CARBON DIOXIDE GAS SENSOR, 433MHZ, 0-40.000PPM, 2 X AA 1.5 VDC BATTERY, IP67

HW Ver.

FW Ver.

Release Date

Functions Change

2.5

5.1

MAY-2021

Innitial FW

WS433-CO2  sensor  utilizes  CMOSens®  Technology  for  IR  detection  enables  carbon  dioxide  measurements  of  the

highest  accuracy  at  a  competitive  price.  Along  with  the  NDIR  measurement  technology  for  detecting  CO2  comes  a

best-in-class  humidity  and  temperature  sensor  integrated  on  the  same  sensor  module.  Ambient  humidity  and

temperature  can  be  measured  by  special  algorithm  expertise  through  modelling  and  compensating  of  external  heat

sources  without  the  need  of  any  additional  components.  The  wireless  portion  is  Sub-GHz  technology  from  Texas

Instruments  allows  long  range  transmission  at  ultra-low  power  consumption.  It  will  connect  2-way  wirelessly  to  the

wireless  co-ordinator  WS433-CL  to  send  data  and  receiving  the  configuration.  It  can  be  configured  the  operation

parameters like data sending interval, health check cycle...remotely from Globiots platform or via ModbusRTU software

(thru the WS433-CL). Its default data rate is 50 kbps, can be switched to 625 bps to increase the communication range.

The sensor can last up to 5 years with 2 x AA battery.

USER GUIDE FOR WIRELESS CO2
SENSOR WITH HUMIDITY &
TEMPERATURE WS433-CO2

This document is applied for the following products

1. Functions Change Log

2. Introduction

Summary of Contents for WS433-CO2

Page 1: ...ough modelling and compensating of external heat sources without the need of any additional components The wireless portion is Sub GHz technology from Texas Instruments allows long range transmission at ultra low power consumption It will connect 2 way wirelessly to the wireless co ordinator WS433 CL to send data and receiving the configuration It can be configured the operation parameters like data...

Page 2: ...0 50 Humidity range resolution accuracy 0 100 RH 0 1 RH 3 0 RH in range 25 100 RH Sensor Filter 316SS sintered filter Sensor housing material Rating SS316 SS304 for Indoor use WIRELESS SPECIFICATION Data speed Up to 50kbps Transmission distance LOS 1000m Antenna Internal Antenna Battery 02 x AA 1 5 3 6VDC up to 5 years operation depends on the configuration Frequency Band ISM 433MHz Sub GHz techno...

Page 3: ...constant default value is 1 b constant default value is 0 So if there is no user setting fora and b Y X The Y value will be compared with Lo and Hi threshold Please refer below the graph of alarm processing For example 1 At default a1 1 and b1 0 We need to calibrate the sensor to a CO2 concentration of50 ppm and 1000 ppm When putting the sensor in an environment with a CO2 concentration of50 ppm a...

Page 4: ...of WS433 CL default 25 The case if Co ordinator is on high position and need to add node sensor We set the sensor as close as possible and set the Rssi_threshold to 80 90 or 100 to increase the sensitivity to allow WS433 CL 04 can add sensors at a longer distance After that perform 2 steps of adding sensors and then reset Rssi_threshold 25 Enb_auto_add_sensors configuration see RF MODE CONFIG in t...

Page 5: ...conds LED blinks twice Release the button to set Data rate RF 625bps Press and hold the button for 10 seconds LED blinks 3 times Release the button to reset RF parameters frequency RF output power data rate if held for more than 30 seconds then the button function does not work You can download Modbus Memmap of WS433 CL with the following link https filerun daviteq com wl id WBbGm89AToHWyvIyMOc780...

Page 6: ...a rate 50 kbps 4 4 Configuration Num of Node will indicate the number of nodes managed by WS433 CL Every time a node is added the Num of Node willincrease by 1 Every time a node is deleted the Num of Node isreduced by 1 Writing Num of Node 0 will delete all 40 node ids to 0 If you want to delete a node id then write it 0 with theWrite function is 16 and the Read function is 3 ...

Page 7: ... the following link https filerun daviteq com wl id qK0PGNbY1g1fuxTqbFW9SXtEvCw7bpc6 Unzip file and run file application Daviteq Modbus Configuration Tool Version Template File https filerun daviteq com wl id ItFaeQgtCmXN98J7GaPdeZvKK5eS1Dd1 How to use the Modbus configuration software ...

Page 8: ...nnect untill the Status displays disconnected to connected It means the WS433 CL 04 is being connected with computer Next we need to import the configuration file for WS433 CL 04 by importing the csv file Go to MENU FILE Import New select the template file Step 3 Configure parameters of the sensor ...

Page 9: ...f sensor Node uint16 Read Hi Byte is error code Lo Byte is sensor type 4 2 4 Humidity value of sensor Node 0 100 RH float Read Humidity value from Wireless CO2 sensor 4 2 4 Temperature value of sensor Node 40 70 C float Read Temperature value of sensor Node 3 1 2 Data status of Node 0 9 99 byte Read 0 9 Interval updated data 99 Disconnected 3 1 2 RF Signal strength of Node 0 4 byte Read From 0 to ...

Page 10: ... to co ordinator regardless any condition Recommended 900 seconds 3 16 2 4 Radio frequency 433 05 434 79 433 Mhz 433 92 float Read Write Configure the operating frequency of wireless sensor by Co ordinator should be configured from 433 05 434 79 MHz only for advanced users 3 16 2 4 a1 1 float Read Write Scale value of parameter_1 a1 Raw sensor value of parameter_1 b1 For sensor value scale 3 16 2 ...

Page 11: ...e following conditions Cycle_healthsta Estimated battery life 900 second 15 minutes 2 89 year 600 second 10 minutes 2 year 300 second 5 minutes 1 year Wireless sensor utilize the ultra low power 433Mhz RF signal to transmit receive data with Wireless co ordinator To maximize the distance of transmission the ideal condition is Line of sight LOS between the Wireless sensor and Gateway In real life t...

Page 12: ...NOTE Integrated WS433 CL iConnector Coordinator The coordinator must be placed at least4 meters above the ground and the sensor clearly visible 6 2 Dimensions 6 2 Antenna Installation ...

Page 13: ...6 3 Bracket mounting 6 4 Filter WARNINGS Please make sure that the operating ambient temperature is right for the sensor ...

Page 14: ... the housing and carefully pull out the top plastic housing in the vertical direction Prepare the professional tools for installation The inappropriate tools may cause damage to the sensor Please avoid contaminating the sensor s filter to ensure accurate measurement 6 4 Battery installation ...

Page 15: ...ery Step 3 Insert the top plastic housing and locking by L hex key ATTENTION REVERSED POLARITY OF BATTERIES IN 10 SECONDS CAN DAMAGE THE SENSOR CIRCUIT ATTENTION When reinstalling the cover pay attention to put the PCB edge into the middle slot of the box inside as shown below ...

Page 16: ... The configuration function of the RF data rate is incorrect Check that the battery is empty or not installed correctly Reconfigure the RF data rate with the button according to the instructions Manufacturer Daviteq Technologies Inc No 11 Street 2G Nam Hung Vuong Res An Lac Ward Binh Tan Dist Ho Chi Minh City Vietnam Tel 84 28 6268 2523 4 ext 122 Email info daviteq com www daviteq com Distributor ...

Page 17: ...Revision 12 Created Wed Jun 2 2021 4 45 AM by Kiệt Anh Nguyễn Updated Fri Jun 25 2021 2 48 AM by Kiệt Anh Nguyễn ...