DS7425, 7425CS (Rev. E, 1/5/07)

1

Perception and Wizard Stations

 

7425

7425CS

Weather Wizard III

®

 Station

The Weather Wizard III station features the 
following: anemometer, inside and outside 
temperature sensors, junction box, and console. The 
console provides A/D conversion, calculations, and data display. A 
DC-power adapter and an 8' (2.4m) cable (for connecting the junction box and console) are included. Options include 
the Rain Collector, and WeatherLink (# 7862) which provides data logging and a serial interface to a computer.

G e n e r a l

Operating Temperature . . . . . . . . . . . . . . . . . . . . . . . . . .  -5° to 140° F (-20° to 60° C)

Display Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . .  32° to 140° F (0° to 60° C)

Supply Power (adapter included) . . . . . . . . . . . . . . . . . . .  16 mA (typical) at 10 to 16 V (100 mA when display is illuminated)

Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Modular (RJ-11, RJ-12, and RJ-45)

Recommended Maximum Cable Length  . . . . . . . . . . . . .  240' (72 m), sensor array to console

Housing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Black ABS plastic

Display Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  LCD

Dimensions

Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5.25" x 5.4" x 3.0" (133 mm x 137 mm x 76 mm)
Display  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4.4" x 1.9" (112 mm x 48 mm)

Weight, total  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3 lbs. 6 oz. (1.53 kg)

S e n s o r   I n p u t s

RF Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  RC low-pass filter on each signal line

D a t a   D i s p l a y e d   o n   C o n s o l e

G e n e r a l

Update Interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16 seconds 

Times and Dates of Maximum and Minimum Values  . . . .  Stored with value

R a i n f a l l   ( r e q u i r e s   R a i n   C o l l e c t o r )

Resolution and Units . . . . . . . . . . . . . . . . . . . . . . . . . . . .  0.01" or 0.2 mm (user-selectable)

Daily Rainfall Range . . . . . . . . . . . . . . . . . . . . . . . . . . . .  0 to 40.95"  (0 to 819 mm)

Total Rainfall Range . . . . . . . . . . . . . . . . . . . . . . . . . . . .  0 to 99.99"  (0 to 9999 mm)

Rainfall Accuracy  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ±(4% + 1 count) for rates from 0.01" to 2" (.2 mm to 50 mm) per hour

±(5% + 1 count) for rates from 2" to 4" (50 mm to 100 mm) per hour

Functions (Period is selected by user) . . . . . . . . . . . . . . .  Total Rainfall for period, Daily Rainfall Amount (alarm)

T e m p e r a t u r e

Outside Temperature (Air)

Resolution and Units  . . . . . . . . . . . . . . . . . . . . . . . .  1 or 0.1°F or 1 or 0.1°C° Celsius is converted from Fahrenheit
Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  -50° to 140° F (-45° to 60° C)
Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ±1°F  (±0.5°C)
Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Current Temperature (high and low alarms), Maximum and Minimum 

Temperatures

Inside Temperature (Air) (sensor located inside console)

Resolution and Units  . . . . . . . . . . . . . . . . . . . . . . . .  1°F or 1°C.°(nominal). Celsius is converted from Fahrenheit  and 

rounded to the nearest 1°C.

Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  32° to 140° F  (0° to 60° C)
Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  ±1°F  (±0.5°C)
Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Current Temperature (high and low alarms), Maximum and Minimum 

Temperatures