Note:    1. For the DVC10-A11KGP1E charger, the maximum continuous working current is 16A, and the cable 

should meet the above requirements. It is recommended to use a 12 AWG cable with a 600Vac withstand voltage 

rating.   

2. For the DVC10-A22KGP1E charger, the maximum continuous working current is 32A, and the cable 

should meet the requirements outlined above. We recommend using a 10 AWG cable with a 600Vac withstand 

voltage rating. However, you can opt for a larger cable size if desired. 

3.    For single-phase AC chargers, the power cable can have a sheath, but its maximum allowable diameter 

should not exceed the range shown in the diagram above; otherwise, assembly cannot be completed. 

4.2 Electrical installation procedure 

Since the connection of the cable is made in the rear plate of the charger, the electrical installation work should be completed 

before the mechanical installation. 

(1) 

Cable pre-treatment 

 

Measure the actual length of the AC power cable according to the installation location of the charger, and pretreat the 
cable   (If possible, crimp the cable to a tubular terminal for subsequent connection) for preparation. 

 

 

Remove the rear plate maintenance cover 

 

 

Use a screwdriver to remove the maintenance cover screws, revealing the terminal connected to the AC cable and the 
power distribution module. 

 

Please keep the maintenance cover and fixing screws aside for future use. 

 

 

A: Wiring terminal;                          B: Maintenance cover plate;  

    

C: Screws;                         

    D: Waterproof seal.  

 

Note:  Be sure not to discard the related parts when removing the maintenance cover, such as waterproof seals and securing 

screws 

(2) 

Pre-install cables 

 

Loosen the waterproof jacket of the cable by turning it counterclockwise. 

 

 

Insert the pre-treated cable into the waterproof jacket, leaving a cable length of approximately 10~15mm based on the 
installation position for easy access to the terminal. 

(Note: Crimping the cable to a tubular terminal is essential for a 

secure connection.) 

 

 

To

 secure the waterproof jacket, turn it counterclockwise until it's tightened. 

 

Loosen the cable waterproof jacket   

Cable and waterproof jacket installation 

 

Summary of Contents for eVO DVC10-A7KGP1E

Page 1: ...1 DAVISeVO EV AC Charger Installation and Operation Manual DVC10 A7KGP1E DVC10 A11KGP1E DVC10 A22KGP1E Document version V1 0...

Page 2: ...sclaimer of Warranties and Limitation of Liabilities The specifications illustrations and information in this manual are based on the latest data provided by our technicians DAVIS LIGHTING reserves th...

Page 3: ...the operational procedures to ensure both your personal safety and the proper functioning of the charger SAFETY WARNINGS Engineers in charge of charger installations must hold electrical licenses in c...

Page 4: ...of charger 12 4 1 General Specification 12 4 2 Electrical installation procedure 13 5 Mechanical installation of the Charger 15 5 1 Installation procedure of power distribution module Optional 15 1 C...

Page 5: ...the product 1 5 How to use this manual It is essential to comprehend all the contents of this manual before using the charger to ensure proper operation 1 6 General Introduction The DAVIS DVC10 series...

Page 6: ...ained in this manual which may help the engineer understand the operation about the Charger 1 8 Product overview 1 Charger main body cover 2 Front cover plate 3 Emergency stop button 4 Maintenance hol...

Page 7: ...lluminated The charger is off RED Solid Green and Red The charger is faulty Yellow Solid Yellow and Green The charger is charging the vehicle X Width of the charger Y Depth of the charger Z Height of...

Page 8: ...t model F Implementation standards C Input characteristics G Production date and bar code D Output characteristics Note The data in the figure is only a reference and does not represent the physical n...

Page 9: ...tion Efficiency 99 5 Rating condition Standby power consumption 5 W Rating condition Current measurement range 10mA 50A 0 5 10mA 25A 0 5 10mA 50A 0 5 Accuracy class Level 1 0 Input protection type Typ...

Page 10: ...astic ABS PC Appearance Size width height depth 230 375 115 mm Tolerance 2mm Network communication 2 4G WIFI Network Networking Protocols Customizable OCPP1 6J Start up method Swipe card to start netw...

Page 11: ...plate should have a bearing capacity of at least 20kg In addition to the above you may also need to prepare the following tools Drilling machine Wire stripper Crimping pliers insulation tape pipe term...

Page 12: ...nt is 32A and the cable must meet these requirements We recommend using a 10 AWG cable with a 600Vac withstand voltage rating However you may also opt for a larger cable size 2 For single phase AC cha...

Page 13: ...power cable according to the installation location of the charger and pretreat the cable If possible crimp the cable to a tubular terminal for subsequent connection for preparation Remove the rear pla...

Page 14: ...If the cable doesn t come loose the connection is secure AC input cable wiring diagram for single phase charger AC input cable wiring diagram for three phase charger Note 1 Engineers can differentiate...

Page 15: ...fy the wire hole for the power distribution module located at the charger s bottom Use appropriate tools like screwdrivers to prepare the wire holes by removing any obstructing material Then open the...

Page 16: ...0kg Refer to the detailed charger installation space requirements as follows Specific technical data parameter Recommended Specification mm A 300 B Indoor installation 900 B Outdoor installation 1300...

Page 17: ...gh technical parameters After installing the rear plate check to ensure it is properly secured and not loose Support rear plate Rear plate install size Installation schematic diagram of the support re...

Page 18: ...unting the gun cable install the necessary parts according to the installation situation Secure the cable in place using cable ties or other suitable methods Site Cleaning Dispose of site debris garba...

Page 19: ...und and the green status indicator will remain on indicating that the charger has started successfully After the charger has started normally ensure that the maintenance cover is restored to its origi...

Page 20: ...stantial damage stop using the charger immediately If feasible perform this check on a monthly basis Remove the maintenance cover on the side of the charger to visually inspect this device Press the T...

Page 21: ...s local representative or after sales service Frequent circuit breaker trips during charger operation Residual current device has a fault 1 Replace the residual current device with one of the same spe...

Page 22: ...N Interruption in the connection between the charger and the router 1 Manually connect the charger to the WIFI LAN 8 DAVIS LIGHTING Service If you have any questions about the product please contact t...

Reviews: