4. Electrical installation of charger
4.1 General Specification
Before performing any electrical installations, ensure that you have a clear understanding of the following electrical regulations
for the charger:
Wiring terminal definition
Cable requirement
Note: 1. For the DVC10-A7KGP1E charger, the maximum continuous working current is 32A, and the cable must
meet these requirements. We recommend using a 10 AWG cable with a 600Vac withstand voltage rating. However,
you may also opt for a larger cable size.
2. For single-phase AC chargers, the power cable can have a sheath, but its maximum allowable diameter should
not exceed the range shown in the diagram above; otherwise, assembly cannot be completed.
For the charger models DVC10-A11KGP1E and DVC10-A22KGP1E, they are suitable for 360-440Vac three-phase AC power
(TN):
Wiring terminal definition
General Requirement