The Wireless Temperature/Humidity Station, referred to as the Temp/Hum 
Station in this manual, is for use with Wireless Vantage Pro

® 

weather stations.

Components

The Temp/Hum Station consists of a temperature and humidity sensor located 
in a radiation shield, plus a sensor interface module and transmitter located in 
a protective housing. 

Tools for Setup

In addition to the hardware provided, you will need some or all of the follow-
ing materials: 

• Small Phillips-head screwdriver

• Adjustable wrench or 11/32" wrench and 7/16" wrench

• Ballpoint pen or paper clip (small pointed object of some kind)

• Drill and 3/16" (5 mm) drill bit (if mounting on a flat, vertical surface)

• Four 1/4" x 1-1/2" (6 x 38 mm) lag screws (if mounting on a flat, vertical 

surface) and a wrench to fit the lag screw hex head.

1-1/2" U-Bolts

1/4" Flat Washers

1/4" Hex Nuts

3-Volt

Lithium

Battery

Mounting 

Bracket

Radiation Shield 

Assembly

Sensor Interface Module Housing

Summary of Contents for 6380 Wireless Temperature/Humidity Station

Page 1: ...cated in a protective housing Tools for Setup In addition to the hardware provided you will need some or all of the follow ing materials Small Phillips head screwdriver Adjustable wrench or 11 32 wren...

Page 2: ...Note on Securing Cables page 11 See Maintenance on page 10 For Technical Support see Contacting Davis Instruments on page 11 Preparing the Temp Hum Station Rotating the Mounting Bracket To facilitate...

Page 3: ...stic latches to release the cover then open the cover You should now be able to see the sensor interface module SIM Re install Mounting Bracket Radiation Shield Assembly Lock Washers Flat Washers 4 Bo...

Page 4: ...ate with each other only when both are set to the same ID Note DIP switch 4 is used for transmission testing and does not affect the ID The factory default transmitter ID setting is 1 Looking at the t...

Page 5: ...2 Press the DONE key to move on to Screen 2 Selecting Transmitters Setup Mode Screen 2 is where you will set the console to recognize signals on that ID as coming from a Temp Hum Station 3 Press the...

Page 6: ...Temp Hum Station 1 First verify that the console is powered and is not in Setup Mode exit Setup Mode by pressing DONE key and holding it for a moment 2 On the Temp Hum Station check that the battery...

Page 7: ...soil if possible Do not install over or near sprinklers The radiation shield is not designed to protect sensors from water that is sprayed upwards If mounting on a building the preferred location is o...

Page 8: ...tion to the mounting bracket using a 8 flat washer 8 split lock washer and 8 hex nut one each of the stud ends Tighten the hex nuts until the station is secure on the mounting bracket 3 Hold the mount...

Page 9: ...ng the holes to ensure that the bracket will be level 2 Slide the stud ends protruding from the top of the station through the holes on the mounting bracket 3 Secure the station to the mounting bracke...

Page 10: ...Keep areas between the shield plates free of debris that may obstruct air flow Examples are leaves twigs webs nests DO NOT remove nesting insects or animals by spraying insect killer of any kind into...

Page 11: ...pport Note Please do not return items to the factory for repair without prior authorization 510 732 7814 for Technical Support Monday Friday 7 00 a m 5 30 p m Pacific Time 510 670 0589 Fax to Customer...

Page 12: ...generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guar...

Reviews: