03/04/2019
EBP25 INSTALLATION INSTRUCTIONS
77 Taras Avenue
P.O. Box 363
Altona North
Vic 3025 Australia
Phone: +61(0)3 9369 1234
Fax: +61(0)3 9369 3456
www.daviescraig.com.au
EBP25 INSTALLATION INSTRUCTIONS
Congratulations on your purchase of the Davies, Craig EBP25.
PLEASE READ ALL THESE INSTRUCTIONS THOROUGHLY BEFORE YOU START WORK.
DON’T RUSH - ENSURE YOU HAVE FULL UNDERSTANDING OF THE WORK AHEAD BEFORE YOU
COMMENCE. ENSURE YOU HAVE ALL TOOLS AND COMPONENTS REQUIRED.
COMPONENTS:
EBP25 - PUMP
EBP25 wiring loom
EBP25 Plug adaptor
NEW EBP25 INSTALLATION
Install the EBP
®
into the hose. If required mount the EBP
®
using attached bracket.
For the best results the EBP
®
should be located low in the system and close to the outlet of
the radiator, intercooler or tank.
You will need to use the EBP25 wiring loom (supplied) when wiring the EBP
®
.
REPLACING EXISTING EBP25 (PART #9005 OR #9105)
Replace your old EBP25
(
part #9005 or #9105) with your new EBP25 and if required
mount the EBP
®
using attached bracket.
To reuse the existing wiring, the EBP25 plug adaptor (supplied) can be used.
WIRING DIAGRAM
NOTE: It’s recommended that a relay (not supplied) is used to supply power to the EBP25.
EBP25 WIRING LOOM
EBP25 PLUG ADAPTOR
Wiring for Control by Thermatic
®
switch
Davies, Craig has a full range of Thermatic
®
Switches available in both mechanical (#0401,
#0404 & #0400) and Digital Thermatic
®
Switches (#0444 & #0500).
Wire the pump as directed by the wiring instructions provided with the Thermatic
®
Switch.
All Davies, Craig Thermatic
®
Switches are
ON/OFF
.
To allow the EBP
®
to run on after hot shutdown, wire the Switch direct to the battery.