8.3. Weitere Probleme und Lösungen
Cause / Solutions
Problem
The unit of the 3D data corresponds to the unit of scale value (usually mm).
In the Advanced Settings under ”Service“, you can enable the ”Debug Conso-
le“. It may show some useful information about the error.
Report the problem to the developers, e.g., on the website in the forum ”Bug
Report“, if it is not known there yet.
During calibration, make sure you have entered the correct scale value of the
calibration pattern. (*)
Fuse the scans with a lower value in the ”Resolution“. But try not to re-import
and fuse your Fusion result again, instead fuse the original aligned scans.
Import your Fusion result into the List of Scans, click the entry with your right
mouse button and select ”Reduce mesh density.“ Then save it with the Save
button below the list – do not Fuse it again.
The most common problem is lack of memory. If possible, use a 64-bit system
and the 64-bit version ”DAVID_x64“. In 32-bit it can help to occasionally restart
DAVID and not work with too many scans simultaneously.
The exported 3D model has an
incorrect scaling
The resolution / file size of the
exported data is too high
Software crash / unexpected
behavior
(*) Requires recalibration