background image

 
 

 
 
 
 

 

PS2

300C

 

USER’S MANUAL 

 

MA20-02/C 

09/11/2011 

 

www.davicia.com 

Summary of Contents for AC1200D

Page 1: ...PS2300C USER S MANUAL MA20 02 C 09 11 2011 www davicia com ...

Page 2: ...TING TROUBLESHOOTING TROUBLESHOOTING TROUBLESHOOTING 13 7 7 7 7 HEIGHT ROD ACCESSORIES HEIGHT ROD ACCESSORIES HEIGHT ROD ACCESSORIES HEIGHT ROD ACCESSORIES 7 1 Height rod assembly 7 2 Battery installation 7 3 Key functions 7 4 Calibrating the height rod 7 5 Using the height rod 7 6 Technical Specifications 14 14 15 16 16 17 18 8 8 8 8 AUTOMATIC AUTOMATIC AUTOMATIC AUTOMATIC HEIGHT ROD ACCESSORIES ...

Page 3: ...USER S MANUAL MA20 02 C 3 1 DESCRIPTION 1 Display unit 2 Mounting holes for height rod accessories 3 Scale platform 4 Adjustable feet 5 Level 1 2 3 4 5 ...

Page 4: ...d o Ensure the voltage marked on the power supply unit matches your main power supply o This device is designed for use indoors o Observe the permissible ambient temperatures for use o The device meets the requirements for electromagnetic compatibility Do not exceed the maximum values specified in the applicable standards 2 2 2 2 1 1 1 1 LOCATION AND SETTING LOCATION AND SETTING LOCATION AND SETTI...

Page 5: ...cription 0 Zero symbol If the scale does not show exactly zero value although the scale pan is unloaded press the 0 0 0 0 key After a short waiting time the scale will be zeroed again Stable symbol If the display shows the stabilization display ο the scale is in the stable condition When the scale is in the unstable condition the stabilization display ο disappears Minor weight Weight under zero LO...

Page 6: ...merical value Entering digits 3 3 3 3 3 3 3 3 WEIGHING WEIGHING WEIGHING WEIGHING Switch on the scale with the ON OFF ON OFF ON OFF ON OFF key The diagnostic scale self check is performed and then the software version is displayed The scale is ready for weighing when the 0 00 kg 0 00 kg 0 00 kg 0 00 kg weight display is shown NOTE If 0 00 kg won t display on the screen press 0 0 0 0 key to zero th...

Page 7: ...ale takes some measuring values and then the calculated average value is displayed o Remove the object baby from the scale platform The object baby s weight reading will remain on the display o Press the HOLD HOLD HOLD HOLD key again to return the scale to the normal weighing mode o HOLD function can be activated before or after putting the weight on the platform In case of weighing babies that mo...

Page 8: ... tare weight For example Press 1 to assign position 1 to preset tare weight The display will blink and makea beep sound NOTE You can assign any other position from 1 5 to pre tare weight Enter Weight Using 0 9 Keys Description Description Description Description Example Example Example Example Press PRE TARE key and the extreme left digit will blink Enter PRE TARE weight using 0 9 keys For example...

Page 9: ...e Long press PRE TARE key for 3 seconds the display will show the blinking m sign Press numeral key 1 5 to choose pre Press numeral key 1 5 to choose pre Press numeral key 1 5 to choose pre Press numeral key 1 5 to choose pre tare value tare value tare value tare value Press ENTER key to confirm the pre tare weight the instrument will automatically perform tare function Press PRE TARE key to retur...

Page 10: ...ected to PC to transfer the weighing results 1 Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu Programs Accessories Communication Hyper Terminal 2 New Connection Description Give new connection a name then click OK 3 Select Your COM Port Click Connect to select your COM port Usually there s only one option for select Then click OK 4 Port Settings Click Bits per second to...

Page 11: ...INT FUNCTION The Weighing BMI and Height results can be printed out for records using RS232 interface cable included in accessory kit which is connected with the round plug at the back terminal After weighing and calculating BMI simply press PRINT PRINT PRINT PRINT key to print out the results The format presented below is the standard format of results print out and cannot be changed ...

Page 12: ...TRUCTIONS FOR REPLACING BATTERIES INSTRUCTIONS FOR REPLACING BATTERIES INSTRUCTIONS FOR REPLACING BATTERIES INSTRUCTIONS FOR REPLACING BATTERIES o Remove the battery cover o Take the battery housing out o Replace new batteries o Make sure batteries are well installed o Reinstall the battery housing 1 Reinstall the battery cover 5 3 5 3 5 3 5 3 ENVIRONMENTAL ENVIRONMENTAL ENVIRONMENTAL ENVIRONMENTA...

Page 13: ...s fault on the scales such as faulty load cell or wiring Please contact the local service representative Counting error too low Indicates that the signal from the load cell is too low This error is normally caused by a serious fault on the scales such as faulty load cell or wiring Please contact the local service representative Zero count over calibration zero range 10 while power on Please recali...

Page 14: ...ht rod to be mounted on the scale with measuring range of 120 200cm AC1200M don t have LCD display instead it automatically transfers the height measurement to weighing scale therefore while calculating BMI the user don t need to enter the height Simply step on the weighing platform and as the weight stabilizes adjust the head piece to measure the height the scale will display the height and BMI r...

Page 15: ...C1200M don t need batteries to operate AC1200D a Remove the battery cover at the rear of indicator b Install 2 AAA size batteries c Put the batter cover back WARNING If the height rod is not in use for long time take out the batteries and store them separately in case of any leakage from battery would damage the measuring rod NOTE When the new batteries have been installed it is recommended to res...

Page 16: ...MI key to check current height o Slide the measuring rod downward completely o If the height display is not 120cm press Reset button to calibrate the height It will be 120cm Keys Keys Keys Keys Description Description Description Description ON OFF Press to switch on and off UNIT To select the measurement unit between cm and inch HOLD To enable value store function during measuring Current height ...

Page 17: ...height transfer function You can calculate BMI with height and weight taken by height rod and scale 1 Slide the measuring rod upward 2 Slide down the head piece until slightly touches the head 3 When the head piece touches the head of the person display will transfer height data to the scale 4 You can use BMI functions of scale to recall and calculate BMI weight and height Connecting USB wire to t...

Page 18: ...nit Reset Button 120 200cm Digital measuring range Measurement range Measurement range Measurement range Measurement range 120 200cm 60 200cm Mechanical measuring range Graduations Graduations Graduations Graduations 1mm Dimensions Dimensions Dimensions Dimensions 40x30x1780mm Weight Weight Weight Weight 0 85kg Power Supply Power Supply Power Supply Power Supply 2 AAA size batteries Temperature ra...

Page 19: ... button to measure the height the scale will display the height and BMI results 8 1 8 1 8 1 8 1 HEIGHT ROD ASSEMBLY HEIGHT ROD ASSEMBLY HEIGHT ROD ASSEMBLY HEIGHT ROD ASSEMBLY 1 AC3200D is delivered with the top part loose and folded Do not pull from this part as cables could get damaged 2 Fix the top part of the height rod using the longest screw 3 Fix the height rod to the scale by screwing the ...

Page 20: ...le O sign to appear on display The scale will beep once Then press the BMI button Height will be automatically measured and shown on display NOTE It is recommended that this action will be assisted to ensure that the person on the platform is standing fully straight at the time of the measurement Otherwise the result may not be exact The result of the height and body mass index appear alternately ...

Page 21: ... 8 4 8 4 8 4 8 4 TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model Model Model Model AC3200D Type Type Type Type Scale mounted automatic height rod Measurement range Measurement range Measurement range Measurement range 0 200cm Graduations Graduations Graduations Graduations 1mm Dimensions Dimensions Dimensions Dimensions 122x530x1630mm Weigh...

Page 22: ...y 300 kg x 100 g LCD Display 1 0 inch LCD display with 5 and 1 2 digits Max external dimensions 340 x 550 x 970 mm Power supply AC adapter 15V 300mA Rechargeable Battery Key Functions ON OFF ZERO PRINT BMI HOLD PRE TARE TARE CLEAR ENTER 0 9 M1 5 Operation temperature 5ºC 35ºC ...

Page 23: ...ified free of charge upon presentation of the purchase receipt for the appliance No other rights can be taken into consideration Return shipment is at the customer s expense if the appliance is anywhere other than at the customer s headquarters In the event of damage during shipment guarantee rights will be granted only if the appliance is shipped in the original packaging You are therefore recomm...

Page 24: ...onas Intended Use Weighing equipment CUMPLE LOS REQUISITOS DE LAS DIRECTIVAS CONFORMS WITH THE REQUISITES OF THE DIRECTIVES EC Directive 2004 108 EC Directiva de Compatibilidad Electromagnética Electromagnetic Compatibility Directive EC Directive 2006 95 EC Directiva de Baja tensión Low Voltaje Directive EC Directive 93 42 EEC Aplicable únicamente a las básculas con aprobación médica Applies only ...

Page 25: ...uments are available on the web www davicia com www davicia com www davicia com www davicia com C Murcia 35 Nave G Pol industrial Can Calderón E 08830 Sant Boi de Llobregat Barcelona Spain Tel 34 93 654 32 32 Fax 34 93 654 16 62 info davicia com www davicia com ...

Reviews: