background image

 

10.

 

Make sure that the total amperes of all the units that are plugged into a single 
wall outlet do not exceed 15 amperes. 

11.

 

Never push objects of any kind into this unit through the cabinet ventilation slots, 
as they may touch dangerous voltage points or short out parts that could result in 
risk of fire or electric shock. Never spill liquid of any kind onto or into this unit. 

12.

 

Except  as  specifically  explained  elsewhere  in  this  manual,  do  not  attempt  to 
service this product yourself. Opening or removing covers that are marked “Do 
Not Remove” may expose you to dangerous voltage points or other risks, and will 
void your warranty. Refer all service issues to qualified service personnel. 

13.

 

Unplug this product from the wall outlet and refer to qualified service personnel 
under the following conditions: 

a.

 

When the power cord is damaged or frayed; 

b.

 

When liquid has spilled into the unit; 

c.

 

When the product has been exposed to rain or water;   

d.

 

When  the  product  does  not  operate  normally  under  normal  operating 
conditions.  Adjust  only  those  controls  that  are  covered  by  the  operating 
instructions in this manual; improper adjustment of other controls may result 
in damage to the unit and may often require extensive work by a qualified 
technician to restore the unit to normal operation; 

e.

 

When the product has been dropped or the cabinet has been damaged; 

f.

 

When  the  product  exhibits  a  distinct  change  in  performance,  indicating  a 
need for service. 

 

Warranty 

Standard Warranty 

 

Datavideo equipment are guaranteed against any manufacturing defects for one 
year from the date of purchase. 

 

The original purchase invoice or other documentary evidence should be supplied 
at the time of any request for repair under warranty. 

 

The product warranty period begins on the purchase date. If the purchase date is 
unknown, the product warranty period begins on the thirtieth day after shipment 
from a Datavideo office. 

Summary of Contents for WM-10

Page 1: ...WM 10...

Page 2: ...o Robotic Pan Tilt Head 7 Introduction 7 Assembly Steps of the WM 10 7 How to install the WM 10 to the Wall 7 Introduction of the Bubble Level Meters of the WM 10 11 Important Notices for installing P...

Page 3: ...plete This manual may contain typing errors omissions or incorrect information Datavideo Technologies always recommend that you double check the information in this document for accuracy before making...

Page 4: ...on To ensure safe and reliable operation of this unit and to protect it from overheating do not block or cover these openings Do not place this unit on a bed sofa rug or similar surface as the ventila...

Page 5: ...b When liquid has spilled into the unit c When the product has been exposed to rain or water d When the product does not operate normally under normal operating conditions Adjust only those controls...

Page 6: ...e are not covered All accessories including headphones cables and batteries are not covered under warranty Warranty only valid in the country or region of purchase Your statutory rights are not affect...

Page 7: ...nserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling...

Page 8: ...sembling the WM 10 wall mount This user manual take PTR 10 as an example Assembly Steps of the WM 10 Please follow following steps for assembling the WM 10 How to install the WM 10 to the Wall Step 1...

Page 9: ...lease align the right side of the round rod to the screw hole of the right side plate according to the following diagram Figure 1 Step9 After that please fix the right side of the round rod to the rig...

Page 10: ...te B to the bottom plate D of the PTR 10 PTR 10T according to the following diagram Figure 1 Step 13 Please align the PTR 10 or PTR 10T to the bottom plate D of the WM 10 Step 14 Please screw four scr...

Page 11: ...10 Figure 1 WM 10 Assembly 1 2 3 4 5 6 7 8 9 10 0 11 0 12 0 13 14 15 16 17 18 19 20 A B C D E...

Page 12: ...is installed horizontally or not The two Bubble Level Meters are located at the bottom of the WM 10 If the bubble is located at the center it means that the surface for mounting the WM 10 is level If...

Page 13: ...150 Series Cameras to WM 10 For installing PTR 10 PTR 10T For installing PTR 10 PTR 10T Robotic Pan Tilt Head to WM 10 it is recommended that all of the six screw holes on both side plates including...

Page 14: ...R 10 PTR 10T to the WM 10 please screw four screws No 9 No 10 No 11 No 12 from the bottom of the bottom plate according to following diagram Figure 2 Installing PTR 10 PTR 10T to WM 10 must be screwed...

Page 15: ...by using internal rails which are located at both side plates For installing the PTC 150 to the WM 10 please follow following steps Step 1 Please make sure that you have the Ceiling Bracket of the PTC...

Page 16: ...5 Step 4 Please install the PTC 150 camera to the Ceiling Lower Covering Plate according to following diagram Step 5 Please install the PTC 150 camera module to the WM 10 according to following diagra...

Page 17: ...ld this product be mounted to metal studs unless an installation professional deems they have been adequately reinforced and will support 4 times the combined weight of Equipment and Wall Mount Please...

Page 18: ...17 Dimensions Unit mm...

Page 19: ...Qty 1 Back Plate 1 2 Side Plate L 1 3 Side Plate R 1 4 Bottom Plate 1 5 Round rod 1 6 Expansion screw 4 7 Hexagon socket screw M5 x 20mm 12 8 Screw Nut M5 4 9 Screw with spring washer M3 x 10mm for mo...

Page 20: ...https www datavideo com product WM 10 G082062864E1 Jan 09 2020 Ver E1 Datavideo Technologies Co Ltd All rights reserved 2020...

Reviews: