RMC150
RS232 Ethernet Controller
For SE500
Instruction Manual
www.datavideotek.com
Rev 260308
Page 1: ...RMC 150 RS 232 Ethernet Controller For SE 500 Instruction Manual www datavideo tek com Rev 260308 ...
Page 2: ...Table of contents Warnings and Precautions 2 Warranty 3 Disposal 3 Packing List 4 Introduction 4 Features 4 Connections 5 Front Panel 5 Operation 6 Specification 8 Service and Support 9 ...
Page 3: ...at the total of the ampere ratings on the products plugged into the extension cord do not exceed the extension cord s rating 10 Make sure that the total amperes of all the units that are plugged into a single wall outlet do not exceed 15 amperes 11 Never push objects of any kind into this unit through the cabinet ventilation slots as they may touch dangerous voltage points or short out parts that ...
Page 4: ...manner other than that specified by Datavideo or has been subjected to abuse or modification will be repaired for time and material charges at the Buyer s expense This warranty does not affect your statutory rights within the Country of purchase Disposal For EU Customers only WEEE Marking This symbol on the product indicates that it will not be treated as household waste It must be handed over to ...
Page 5: ... Instruction Manual Introduction The Datavideo RMC 150 is a remote control box for the SE 500 It allows the SE 500 to be controlled from a PC via an Ethernet connection Features Ethernet to RS 232 remote controller for the Datavideo SE 500 LED Ethernet Communication Indicator Compact design Built in mounting plate for easy installation Locking 2 1mm in line DC In socket 12V 300mA power requirement...
Page 6: ...ity N B If you are connecting directly to a PC not via a hub please use a CAT 5 Crossover Cable not supplied RS 232 Port Connect this to your SE 500 vision mixer RS232 Control Port with the supplied cable Power In Socket Connect the supplied power supply to this socket Please note the socket is labelled 12v 300mA whereas the power supply is 12V 500mA this is intentional ...
Page 7: ...emote port 1024 In order to communicate with the RMC 150 your PC must be set to an appropriate IP Address Go into Network Connections on your PC and set the IP Address to a suitable value As an example IP Address 192 168 0 90 Subnet Mask 255 255 255 0 Default Gateway 192 168 0 0 Open the folder RMC_150_UI and double click on SE500 exe to launch the User Interface UI Once the UI is displayed right ...
Page 8: ...If the connection is established the virtual buttons on the UI will light up the same as the actual SE 500 You can now control the SE 500 by clicking on the virtual buttons To close the application right click anywhere on the UI and select EXIT from the drop down menu ...
Page 9: ...buttons do not light up The most likely causes of this are You are not using the correct type of CAT 5 cable Crossover for connection directly between the RMC 150 and a PC Straight through for connection via a hub Your PC is not set to an appropriate IP Address Go into network settings and set the IP address correctly ...
Page 10: ...5 RJ45 Input 100 10 Base T RS 232 Sub D 9 Pin I O Port DC In Socket 2 1mm In Line DC Jack Lockable Dimensions Incl Mounting Plate 10 x 6 7 x 2 4 cm L x W x D Weight 176g Specifications are subject to change without notice ...
Page 11: ...tavideo nl www datavideo info Datavideo UK Limited Unit 2 Waterside Business Park Hadfield Glossop Derbyshire SK13 1BE UK Tel 44 1457 851000 sales datavideo co uk www datavideo info Datavideo Technologies Co Ltd 10F 176 Jian Yi Rd Chung Ho City Taipei Hsien Taiwan 235 Tel 886 2 8227 2888 service datavideo com tw www datavideo com tw Datavideo Technologies China Co 2F D 2 Lane 777 West Guangzhong R...