89
Appendix 3
Firmware Upgrade
Datavideo usually releases new firmware containing new features or reported bug fixes from time to
time. Customers can either download the ShowCast-100 firmware as they wish or contact their local
dealer or reseller for assistance.
This section outlines the firmware upgrade process which should take approximately 10 minutes to
complete. The existing ShowCast-100 settings should persist through the firmware upgrade process,
which should not be interrupted once started as this could result in a non-responsive unit.
Keyboard / Mainboard
Successful firmware upgrade on ShowCast-100 requires:
ShowCast-100 x 1
12V Power adapter x 1
USB thumb drive x 1
Latest firmware files
Update Procedure
1.
Download the latest firmware files from the official product page.
2.
Save the files on the USB thumb drive.
3.
Insert the thumb drive into the F/W Upgrade port.
4.
Open OSD menu then select Setup
Firmware Upgrade
Update
5.
The ShowCast-100 will perform a firmware upgrade automatically and restart as soon as the
upgrade is complete.
Video Streaming Server
To update the video streaming server, you will need:
The latest firmware for the video streaming server.
This firmware file can be obtained from your local Datavideo office or dealer or product page.
ShowCast-100 x 1
12V Power adapter x 1
Update Procedure
1.
Visit the official product page
https://www.datavideo.com/tw/product/showcast100
the latest firmware file
.
2.
Login the streaming encoder’s web interface, then click the System tab to open the system
configuration page.
3.
Scroll down to Firmware Update then click the Browse button to search for the latest firmware file
on the PC’s hard disk.