TEST
PRODUCT REFERENCE GUIDE
41
TEST
The TEST function can be activated by keeping TEST signal HIGH (
pin 2 on TX unit
) for at
least 0.5 seconds as shown in the following timing diagram.
The TEST disables the emission stage, so the RX side sees interrupted beams (all) and
the OSSD goes low within response time. As is shown in the timing diagram below, the
OSSDs go OFF (BREAK status) after 0.5s (plus a cycle time) and after the response time
of the light curtain.
Figure 10: OSSDs timing for test on TX
NOTE: On Body models only, TEST input may be used to set Emission
Range. Refer to the next paragraph for more information.
CAUTION: At runtime keep TEST input connected to 24Vdc for more than 2s
and less than 5s to change range setting from Long to Short or vice versa.
Emission Range setting is kept also after a power cycle. Refer to the next
paragraph for more information.
TEST
24Vdc
EMISSION STATUS
OSSDs STATUS
0.5s
0V/FLOAT
OFF
ON
SAFE
BREAK
RESPONSE TIME
RECOVERY TIME
2s
Summary of Contents for SH4 BASE-STANDARD
Page 1: ...SH4 BASE STANDARD PRODUCT REFERENCE GUIDE Safety Light Curtains...
Page 6: ...CONTENTS vi SH4 BASE STANDARD...
Page 13: ...COMPLIANCE PRODUCT REFERENCE GUIDE 5...
Page 29: ...GENERAL INFORMATION ON DEVICE POSITIONING PRODUCT REFERENCE GUIDE 21...
Page 33: ...PRODUCT REFERENCE GUIDE 25...
Page 38: ...ELECTRICAL CONNECTIONS 30 SH4 BASE STANDARD...
Page 59: ...SH4 X XXXX X X MODELS PRODUCT REFERENCE GUIDE 51...
Page 65: ...PRODUCT REFERENCE GUIDE 57...
Page 69: ...RESPONSE TIMES PRODUCT REFERENCE GUIDE 61...
Page 73: ...SH4 2 3 4 XXXX X X PRODUCT REFERENCE GUIDE 65...
Page 75: ...METAL ANGLED FIXING BRACKET PRODUCT REFERENCE GUIDE 67...