SECTION 2
2-1
001-3282-101/102
MODEM SETUP
2.1 INTERCONNECT CABLE INSTALLATION
2.1.1 INTRODUCTION
The modem requires a power source with an operating voltage range of 7 - 16 Vdc.
NOTE: Transceiver
may require a more restricted operating range.
Interconnect cables are available from DRL. Contact your sales
representative for details.
Table 2-1 3282 INTERCONNECT CABLES
The external connector on the modem is a 3M-type male 10-pin ribbon connector. As shown in Figures 2-
1 and 2-2, only one power connection is required. Also shown in Figures 2-1 and 2-2 are the pin designations for
these connectors. Install these cables as required for your particular installation.
Figure 2-1 DL-3400 EXTERNAL CONNECTOR
TRANSCEIVER
MODEL
DRL CABLE #
CONNECTOR TYPES
DL-3400
023-3410-125
10-Pin (2)
*
(to spade terminals)
RNet
/ JSLM
697-3282-012
DE-15 (1) & DA-15 (1)
*
MODEM 10-PIN CONNECTOR ASSIGNMENTS
PIN
FUNCTION
TYPICAL
COLOR
1
2
3
4
5
6
7
8
9
10
BROWN
BLUE
VIOLET
GREEN
RED
ORANGE
GRAY
YELLOW
BLACK
WHITE
Wideband Out
Wideband In
NOT USED
NOT USED
SUPPLY VOLTAGE (+)
TX KEY (PTT) OUT
CARRIER DETECT IN
TX NARROW BAND DATA OUT
GROUND (-)
RX NARROW BAND DATA IN
MO
DE
M
TR
AN
SC
EI
VE
R
1
2
9
10
10-Pin Connector Pinout
Note: Using Pins 1 & 2 to transmit data is
not
FCC approved.
PART NO. 023-3410-125
(length: 3 ft.)