Step 3: Calibrate the RFID Tag 

 

To establish the critical tag to transducer distance setting and nominal power requirements, the printer 

features two different RFID tag calibration methods: Quick and Standard. As shown below, while the 

amount of operator interaction differs, both calibration methods accomplish the same result. Before 

calibrating for the RFID tag, ensure the following: 

 

1) 

That RFID media has been loaded;  

2) 

That the printer’s media sensor has been calibrated for the RFID media; and,  

3)

  That the RFID Option has been enabled in the 

PRINTER OPTIONS

 menu.  (Consult the 

Operator’s 

Manual

 for details on these procedures and settings.) 

 

 

 

To calibrate the RFID Tags, choose your method then execute the steps accordingly, as explained below: 

 

 

To perform the Quick RFID Tag Calibration – 

 

 

With the printer at READY, simultaneously press both the 

FEED Key 

and the 

TEST Key

.

 

 
 

 

To perform the Standard RFID Tag Calibration –

 

 

1)

  Press the 

MENU Key

 then scroll to 

PRINTER OPTIONS

 and press the 

ENTER Key

.  

2)

  Scroll to 

RFID

 then press the 

ENTER Key

3)

  Scroll to 

PERFORM CALIBRATION

 then press the 

ENTER Key

.

 

   

Using either method, you will be prompted to 

PERFORM CALIBRATION?

 Selecting 

YES

 at the prompt 

will start the two-part calibration process (while selecting 

NO

 will exit this menu).  

 
If 

YES

 was selected, 

CALIBRATING RFID

 will be displayed as the media advances to begin tag location 

scanning. Once this location is established, power calibration begins. (Wait briefly while these processes 

finish.)   

 
Upon completion, the printer will retract the media to the TOF position, update its database information, 

and display the RFID position and power results (along with a brief SUCCESS or FAILURE message).   

 