SG BODY REFLECTOR MUTING
37
6.5.2 SG4-
RB…-N Models EDM Function and Connection
This function can be activated or deactivated with dip-switches 6.
To correctly use this function:
•
activate it using the corresponding dip-switches;
•
connect pin1 to +24 VDC through the normally closed contacts of the device to be monitored.
This function checks that the normally closed contacts switch state when the OSSD outputs change state.
Figure 36 - Connection of EDM (for SG4-RB...-N models)