background image

 

 

 

 
 
 
 

SG2-B SERIES

 

 

Safety light curtains with infrared beams

  

 
 

QUICK GUIDE 

 
 

SAFETY INFORMATION 

 

The following points must be observed for a correct and safe use 

of the safety light curtains of the SG2 series: 

 

 

 The stopping system of the machine must be electrically controlled. 

 This control system must be able to stop the dangerous movement of the machine within the total machine stopping 

time T as per par. 1.1.3 of the manual included in the CD supplied and during all working cycle phases. 

 Mounting and connection of the safety light curtain must be carried out only by qualified personnel, according to the 

indications included in the special sections (refer to sections 2; 3; 4; 5) and in the applicable Standards. 

 The safety light curtain must be securely installed so that access to the dangerous zone is not possible without 

interrupting the beams (see section 2 

“Installation mode

”). 

 The personnel operating in the dangerous area must be well trained and must have adequate knowledge of all the 

operating procedures of the safety light curtain. 

 The TEST/RESET button must be located outside the protected area as the operator must check the protected area 

during all Test and Reset operations. 

 Please carefully read the instructions for the correct functioning before powering the light curtain. 

 
Precautions to be observed for the choice and installation of the device 
 

 

Make sure that the protection level assured by the SG2 device (Type 2) is compatible with the real danger 

level of the machine to be controlled, according to EN 954-1 and EN 13849-1. 

 

 The outputs (OSSD) of the ESPE must be used as machine stopping devices and not as command devices. The 

machine must have its own START command. 

 The dimension of the smallest object to be detected must be larger than the resolution level of the device. 

 The ESPE must be installed in a room complying with the technical characteristics indicated in chapter 10 “

Technical 

data

” of the manual included in the CD supplied. 

 Do not place the device near intense and/or flashing light sources and, in particular, close to receiving unit front surface. 

 

The presence of intense electromagnetic disturbances could jeopardise device operation. 
This condition has to carefully evaluated with the support of the DATALOGIC AUTOMATION Technical service.  

 The operating distance of the device can be reduced in presence of smog, fog or airborne dust. 

 A sudden change in environment temperature, with very low minimum peaks, can generate a small condensation layer 

on the lenses and so jeopardise functioning. 

 

 

The failure to respect the safety distance reduces or cancels ESPE the protection function. 

For more detailed information about calculation of safety distance,please refer to the complete manual 

contained in the CD supplied. 

Summary of Contents for SG2-B Series

Page 1: ...e light curtain Precautions to be observed for the choice and installation of the device Make sure that the protection level assured by the SG2 device Type 2 is compatible with the real danger level of the machine to be controlled according to EN 954 1 and EN 13849 1 The outputs OSSD of the ESPE must be used as machine stopping devices and not as command devices The machine must have its own START...

Page 2: ...tatus as shown in the table Correct alignment procedure The light curtain alignment can be effected only after having completed the mechanical installation and the electrical connections The following procedure has to be followed Check the green LED and the yellow LED on the TX unit If ON the emitter is running correctly Verify that the sensitive area from the safety light curtain is free Verify t...

Page 3: ...d ON Light curtain working and in safety block conditions Function Type Check and repair LED OSSD error yellow and red BLINKING Check OSSD connections make sure that they are not in contact with one another or with the supply cables then Reset If the failure continues contact DATALOGIC AUTOMATION Internal error red ON yellow BLINKING Switch OFF and switch ON the supply circuit if the failure conti...

Page 4: ...efective during the warranty period of 36 months from the manufacturing date This warranty does not cover damage or liability deriving from the improper application of DATALOGIC AUTOMATION products DATALOGIC AUTOMATION Via Lavino 265 40050 Monte S Pietro Bologna Italy Tel 39 051 6765611 Fax 39 051 6759324 www automation datalogic com e mail info automation it datalogic com DATALOGIC AUTOMATION car...

Reviews: