background image

S80-MH-5-YL09 

Distance sensor with laser emission and time of flight 
measurement

INSTRUCTION MANUAL 

CONTROLS 

FRONT INDICATORS LED 

OUTPUT LED  

The yellow LED ON indicates the OR function of the OUT1 and OUT2 outputs (one of the 2 outputs is 
active). 

ALARM LED  

The red LED ON indicates the absence of signal. 

COMMAND PANEL AND DISPLAY 

OUTPUT LED  

The yellow LED ON indicates the logic OR function of the two OUT1 and OUT2 outputs (one of the 2 
outputs is active). 

DISPLAY (4-digit green coloured display) 

In the normal mode, the display indicates the detected distance, in millimetres. 
The "LLLL" message on display means distance under the minimum value. 
The "HHHH" message on display means distance over the maximum value. 
The "FFFF" message on display means low signal received condition. 

OUT1, OUT2 LEDs 

The n.1 and n.2 green LEDs ON indicate the activation of the OUT1 and OUT2 outputs. 

LED 3 

The n.3 green LED does not indicate any function. 

SET PUSHBUTTON 

A pressure on the pushbutton allows the selection of one of the following options: 

-

 measurement 

range 

teach-in 

-

 

switching thresholds teach-in 

-

 

setting and visualisation parameters menu 

+/- PUSHBUTTONS 

A light pressure on these pushbuttons allows the user to run through the menu of the sensor 
parameters and setting  menu. 
Moreover, a long pressure allows to change the switching threshold value, as indicated in the 
“SWITCHING THRESHOLD ADJUSTMENT” paragraph. 

INSTALLATION 

The sensor can be positioned by means of the three housing’s holes using screws (M5x40 or longer) 
with nuts and washers.  
Various orientable fixing brackets to ease the sensor positioning are available (please refer to the 
accessories listed in the catalogue). 
The operating distance is measured from the front surface of the sensor optics. 
The M12 connector can be oriented at two different positions (refer to figure). 

CONNECTIONS 

M12 CONNECTOR 

NOTE: the wire colours are referred to the cables manufactured according to the European 
standard. 

TECHNICAL DATA 

Power supply: 

15 … 30 VDC limit values 

Class 2 (Type 1) UL 508 

Ripple:

2 Vpp max.

Consumption 
(output current excluded): 

170 mA max (110 mA @ 24 V)  

Outputs: 

2 PNP or NPN outputs 

30 VDC max.

 

(short-circuit protection) 

analogue output with 4-20 mA 

Serial interface: 

RS485, 9600Bd, 8N1 

SYNC input: 

PNP 

Measurement range: 

      300 … 7000 mm (90% white)  
      300… 4000 (18% grey) 
      300 … 2500 mm (6% black) 

Linearity: 

0.3% (24VDC, 25°C, with 90% white target) 

Repeatability: 

7 mm @ 7m 

Hysteresis:

5 mm

Temperature drift: 

< 0.6 mm/°C 

Output current: 

100 mA max. 

Output saturation voltage: 

 2 V 

Response time: 

6 ms  

Response time for analogue 
output: 

Max.Variation from 0.3 to 7 m = 40 msec 

Switching frequency: 

85 HZ 

Warm up 

20 min 

Indicators: 

command panel

4-digit display (GREEN), OUTPUT LED (YELLOW) 

2 OUT1, OUT2 LEDs (GREEN) 

Indicators LED

OUTPUT LED (YELLOW) / ALARM LED (RED) 

Setting: 

SET, +, - pushbuttons 

Data retention: 

non volatile EEPROM memory 

Operating temperature: 

-10 … 50 °C 

Storage temperature: 

-20 … 70 °C 

Electrical shock protection: 

Class 2 

Typical spot dimension: 

 12 mm at 2 m 

 20 mm at 4 m 

  

 40 mm at 6 m 

Emission type: 

Red laser (658 nm) Class 2 (

 658 nm)  

EN 60825-1 

Ambient light rejection: 

According to EN 60947-5-2 

Vibrations: 

0.5 mm amplitude, 10 … 55 Hz frequency, for every axis 

(EN60068-2-6) 

Shock resistance: 

11 ms (30 G) 6 shock for every axis (EN60068-2-27) 

Housing material: 

aluminium 

Lens material: 

Window and lenses in glass 

Mechanical protection: 

IP67 

Connections: 

M12-8 pole connector 

Weight:

330 g. max.

DIMENSIONS 

MEASUREMENT RANGE TEACH-IN 

Legend:

 

pushbutton 

pressed

  pushbutton not pressed  

LED 

on

 LED 

off 

 

Measurement range teach-in is effected placing directly the object to detect in front of the 
sensor, according to the following procedure: 

- Detection 

- Place the object in front of the sensor to distance that is to be detected detect as 

minimum or maximum distance 

OUT

Display

Keyboard

OR

1

2

3

Dig1

Dig2

Dig3

Dig4

+

SET

-

1

9

4

5

Press the SET pushbutton for at least 4s, until the “d_Lo”  message appears . 

OR

1

2

3

Dig1

Dig2

Dig3

Dig4

+

SET

-

d

_

L

o

-  Minimum – Maximum distance selection: 

-

 

+/- buttons pressure permits to select among following options: 

1.  minimum distance (“d_Lo”)

2.  maximum distance (“d_HI”)

3.  range selection menu exit, without saving any values (“ESC”)

4.  restoring of the standard measurement range, 300 mm – 7000 mm (“rES”)

OR

1

2

3

Dig1

Dig2

Dig3

Dig4

+

SET

-

d

_

L

o

   

d

_

H

I

E

S

C

-

r

E

S

-

Exit without saving any values 

-  To exit the menu without saving any value select “ESC”  
-  Push the SET button for at least 0.5s  

Exit  restoring the standard range 300mm – 7000mm 

-  To exit the menu restoring the standard range 300 mm – 7000mm select  “rES”  
-  Push the SET pushbutton for at least 0.5s  

-  Target detection phase 

-

 

Selec  “d_Lo” or  “d_HI” options  

-

 

Push the SET pushbutton for at least 0.5s .  

-

 

The “uPdt” message begins to blink (4Hz, per 3 s).  

OR

1

2

3

Dig1

Dig2

Dig3

Dig4

+

SET

-

u

d

t

-

 

Detection distance value appears. 

-

 

The +/- pushbuttons can be used to ch’ange the detected distance value. 

OR

1

2

3

Dig1

Dig2

Dig3

Dig4

+

SET

-

1

4

5

-

 

The units ch’ange if these pushbuttons are pressed repeatedly, the tens if kept 

pressed.  

-

 

Press the SET pushbutton again for at least 0.5s to end the detection phase . 

OR

1

2

3

Dig1

Dig2

Dig3

Dig4

+

SET

-

1

4

5

SETTING OF THE 2 CHANNELS 

Legend:

 

pushbutton 

pressed

  pushbutton not pressed  

LED 

on

 LED 

off 

 

The switching threshold setting for each of the 2 channels and the selection of the logic 
switching is effected placing directly the object to detect in front of the sensor, according 
to the following procedure: 

-  Detection 

- Place the object to detect in front of the sensor. 

OUT

Display

Keyboard

OR

1

2

3

Dig1

Dig2

Dig3

Dig4

+

SET

-

1

9

4

5

Press the SET pushbutton for at least 2 s. 

-

 

The “CH-1” message appears. 

OR

1

2

3

Dig1

Dig2

Dig3

Dig4

+

SET

-

C

H

-

1

 

Channel selection 

-

 

To select the channel setting use the +/- pushbuttons. 

OR 1 2 3 Dig1

Dig2

Dig3

Dig4

+

SET

-

 

 

 

 

C

H

-

1

 

 

 

 

C

H

-

2

 

 

 

 

E

S

C

-

Exit without saving any value 

-  To exit the menu select “ESC” without saving any value select “ESC” 
-  Push the SET button for at least 0.5s  

-  Switching threshold teach-inDARK/LIGHT selection 

-

 

Select  “CH1” or “CH2” options  

-

 

Press the SET pushbutton again for at least 0.5 s. 

-

 

The “L On” message appears. 

OR 1 2 3 Dig1

Dig2

Dig3

Dig4

+

SET

-

 

 

 

 

L

O

n

-

 

To select the DARK/LIGHT mode of the channel use the +/- pushbuttons. 

-

 

“L on” is visualised when the LIGHT mode is selected; “d On” in case of DARK mode 

OR 1 2 3 Dig1

Dig2

Dig3

Dig4

+

SET

-

 

 

 

 

L

O

n

 

 

 

 

d

O

n

-  Target detection phase 

-

 

Press the SET pushbutton for at least 0.5 s, the  “uPdt” message begins to blink (4Hz, for 2 s). 

OR 1 2 3 Dig1

Dig2

Dig3

Dig4

+

SET

-

 

 

 

 

u

d

t

-

 

The detection distance value appears. 

-

 

The +/- pushbuttons can be used to change the detected distance value. 

OR 1 2 3 Dig1

Dig2

Dig3

Dig4

+

SET

-

 

 

 

1

4

5

-

 

The units change if these pushbuttons are pressed repeatedly, the tens if kept 

pressed.  

-

 

Press the SET pushbutton again for at least 0.5 s. to end the detection phase. 

OR 1 2 3 Dig1

Dig2

Dig3

Dig4

+

SET

-

 

 

 

1

4

5

SWITCHING THRESHOLD ADJUSTMENT 

OUT 

Display

Keyboard

OR 1 2 3 Dig1

Dig2

Dig3

Dig4

+

SET

-

 

 

 

1

9

4

5

Press the +/- pushbuttons for at least 2 s. 

The “CH-1” message appears. 

OR 1 2 3 Dig1

Dig2

Dig3

Dig4

+

SET

-

 

 

 

C

H

-

1

Channel selection 

-

 

Use the +/- pushbuttons to select the channel to detect. 

OR 1 2 3 Dig1

Dig2

Dig3

Dig4

+

SET

-

 

 

 

C

H

-

1

 

 

 

C

H

-

2

Distance of threshold phase 

-

 

Press the SET pushbutton for at least 0.5 s. 

-

 

The previously detected distance value appears. 

-

 

Use the +/- pushbuttons to change the detected distance value. 

-

 

The units change if these pushbuttons are pressed repeatedly, 

the tens if kept pressed. 

OR 1 2 3 Dig1

Dig2

Dig3

Dig4

+

SET

-

 

 

 

1

4

5

-

 

Press the SET pushbutton again for at least 0.5 s. to end the adjustment phase. 

OR 1 2 3 Dig1

Dig2

Dig3

Dig4

+

SET

-

 

 

 

1

6

0

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]