This product is covered by one or more of the following patents.
European Patent 1,111,690 B1
S5N-Px-...-PK/NK SERIES
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (S5N-
…A00/B01/C01/C10/F00)
The yellow LED ON indicates that the NO output status is closed.
POWER ON LED (S5N-
…G00)
The green LED indicates that the sensor is operating.
TRIMMER (S5N-
…B01/C01)
The trimmer can be used to adjust sensitivity; the operating distance increases
turning the trimmer clockwise.
WARNING: The trimmer rotation is limited to 270°.
Do not apply excessive torque beyond the maximum and minimum pos it i o n s
(max 40 Nmm).
INSTALLATION
The sensor can be fixed by means of the M18x1 threaded body through
a
18mm hole, using the specific washer and the two CH.24 nuts
(1.5Nm maximum tightening torque) or CH.22 nuts, h=8mm, (2Nm
maximum tightening torque) enclosed. Alternatively, the sensor can be
mounted through the two housing’s holes using two screws (M3x22 or
longer) and washer.
Amongst the various possible solutions, we suggest to choose the
combination that offers the best visibility of the signalling LEDs and the
easiest access to the trimmer.
Various
orientable fixing brackets are
available to ease the sensor positioning
(please refer to the accessories listed in the
general catalogue). The operating distance is
measured from the front surface of the sensor
lens.
C models
: To improve the detection, the
object has to be moved closer or further away
from the front surface of the sensor lens.
In case of lateral translation, the object must move as indicated in the
figure.
CONNECTIONS
The connections are compliant to the EN 60947-5-2 standard.
S5N-
…A00/B01/C01/C10/F00
+
10 … 30 Vdc
DARK- / LIGHT+
BROWN
1
WHITE
2
BLACK
4
BLUE
3
N.O. OUTPUT
0 V
*
S5N-
…G00
+
10 … 30 Vdc
TEST +
BROWN
1
WHITE
2
BLACK
4
BLUE
3
TEST -
0 V
*
in case of white wire or pin 2 not connected the sensor works in
LIGHT mode for proximity models (C01/C10) and in DARK mode for
retroreflex (A00/B01) and receiver (F00).
M12 CONNECTOR
S5N-
… A00/B01/C01/C10/F00
S5N-
…G00
DIMENSIONS
TECHNICAL DATA
S5N-PA AXIAL VERSION
S5N-PR RADIAL VERSION
Power supply:
10 … 30 Vdc (limit values)
Ripple:
2 Vpp max.
Current consumption
(output current excluded):
30 mA max.
Outputs:
N.O.; PNP or NPN
(short circuit protection)
Output current:
100 mA max.
Capacitive load:
C
max
<= 1.5 uF @24V, I
load
= 100mA
C
max
<= 3.5 uF @24V, I
load
= 10mA
Output saturation voltage:
2 V max.
Response time:
1 ms (4 ms mod.F00)
Switching frequency:
500 Hz (120 Hz mod.F00)
Indicators:
OUTPUT LED (YELLOW) mod.G00 excluded
POWER ON LED (GREEN) (mod.G00)
Setting:
sensitivity trimmer (mod.B01/C01)
Operating temperature:
-
25 … 55 °C
Storage temperature:
-
25 … 70 °C
Insulating strength:
500 Vac 1 min., between electronics and housing
Insulating resistance:
>20 M
500 Vdc, between electronics and housing
Operating distance
(typical values):
A00: 0.1…3.5 m on R2
B01: 0.1…2.5 m on R2
C01: 1…40 cm
C10: 0…10 cm
F00/G0
0: 0…18 m
A00: 0.1
…2.5 m on R2
B01: 0.1…2.0 m on R2
C01: 1…30 cm
C10: 0…8 cm
F00/G00: 0…15 m
Emission type:
RED (660 nm) (mod.B01) / INFRARED (880 nm) (mod.A00/C01/C10/G00)
Ambient light rejection:
according EN 60947-5-2
Vibrations:
0.5 mm amplitude, 10
… 55 Hz frequency, for every axis (EN60068-2-6)
Shock resistance:
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
LIGHT/DARK selection:
white wire or pin 2 connected to +10…30V LIGHT mode; to 0V DARK mode
white wire or pin 2 not connected
LIGHT mode (mod.C01/C10);
DARK mode (mod.A00/B01/F00)
Housing material:
PBT
Lens material:
PMMA
Mechanical protection:
IP67
Connections:
2 m cable
4 mm / M12 - 4 pole connector
Weight:
75 g. max. cable vers. / 25 g. max. connector vers.
AtEx 2014/34/EU
II 3D EX tc IIIC IP67 T85°C
SETTING
Setting of S5N-
…A00/B01
Position the sensor and reflector on opposite sides.
Moving the sensor both vertically and horizontally, determine the power
on and off points of the yellow LED (OUT) and then mount the sensor in
the middle of the points defined.
B01 Model
: Turn the sensitivity trimmer to the maximum position.
If necessary reduce sensitivity in order to detect very small targets. In
order to improve alignment, repeat the procedure detailed above whilst
progressively reducing the sensitivity.
Setting of S5N-
…F00/G00
Position the sensors on opposite sides.
Move the sensor both vertically and horizontally, determine the power on
and off points of the yellow LED (OUT) and then mount the sensor in the
middle of the defined points.
Setting of S5N-
…C01
Turn the sensitivity trimmer to minimum: the yellow
LED is OFF.
Position the target to detect in front of the sensor.
Turn the sensitivity trimmer clockwise until the yellow
LED turns ON
(Target detected state, pos.A).
Remove the target, the yellow LED turns OFF.
Turn the sensitivity trimmer clockwise until the yellow LED turns ON
(Background detected state, pos.B).
The trimmer reaches the maximum level if the background is not
detected.
Turn the trimmer to the intermediate C position, between the two A and
B positions.
Setting of S5N-
…C10
The operating distance range of these sensors is factory preset: please
consider this feature when positioning.
TEST FUNCTION (S5N-
…G00)
The TEST+ and TEST- inputs can be used to inhibit the emitter and
verify that the system is correctly operating.
The receiver output should switch when the test is activated while the
beam is uninterrupted. The inputs activating voltage range is 10 … 30
Vdc, whilst respecting the polarity.
The emission is switched off connecting TEST+ to Vdc and TEST- to 0V.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com:
Contact Us,
Terms and Conditions,
Support
.
The warranty period for this product is 36 months. See General Terms and Conditions
of Sales for further details.
For information about the disposal of Waste Electrical and
Electronic Equipment (WEEE), please refer to the website at
© 2021 Datalogic S.p.A. and/or its affiliates
ALL RIGHTS RESERVED.
Without
limiting the rights under copyright, no part of this documentation may be reproduced,
stored in or introduced into a retrieval system, or transmitted in any form or by any
means, or for any purpose, without the express writ ten permission of Datalogic S.p.A.
and/or its affiliates. Datalogic and the Datalogic logo are registered trademarks of
Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks
and brands are property of their respective owners. Datalogic reserves the right to
make modifications and improvements without prior notification.
821007360 Rev.A
MIN
MAX
A
B
C