CONTROLS 

OUTPUT LED 

The yellow LED indicates the output status. 

STABILITY LED (S3Z…B01/F01) 

The green LED ON indicates that the received signal has a safety 
margin greater than 20% compared to the output switching value. 

POWER ON LED (S3Z…G00) 

The green LED indicates that the sensor is operating. 

TRIMMER (S3Z…B01/F01) 

The trimmer can be used to adjust sensitivity; the operating 
distance increases turning the trimmer clockwise. 

ADJUSTMENT SCREW (S3Z…M01) 

This control can be used to adjust the cutoff distance (6 turns 
screw); the operating distance increases turning the control 
clockwise. 

LIGHT/DARK TRIMMER 

This switch can be used to set light or dark operation mode. 
 

WARNING (only for S3Z…B01/F01): 

The trimmer rotation is limited to 250° by a mechanical stop. 

Do not apply excessive torque when adjusting (max 0.05 Nm). 
 

INSTALLATION 

-  Do not apply excessive impact on 

the sensor during the installation 
process, so as to prevent damage 
or deterioration in the degree of 
protection. 

-  To install the sensor, tighten the 

mounting screws to a torque of 
0.5 Nm or less. 

Install the Background 
suppression type sensor head 
perpendicular to the object 
transfer as shown below to minimize sensing errors. 

 

 

CONNECTIONS 

The connections are compliant to the EN 60947-5-2 standard. 

S3Z…B01/F01/M01 

 

+

BROWN 

BLACK

1

4

10…30 VDC

BLUE 

3

0 V 

OUTPUT

 

 

S3Z…G00 

 

+

BROWN 

1

10…30 VDC 

BLUE 

3

0 V

 

M8 CONNECTOR 

 

 

2

1

4

 

3

 

 

TECHNICAL DATA 

 

 

S3Z…B01

 

S3Z…F01/G00

 

S3Z…M01

 

Power supply: 

12 … 24 VDC (operating limit 10…30VDC); (Class 2 UL508) reverse polarity protected 

Ripple: 

p-p 10% max. 

Current consumption 
(output current excluded): 

35mA max. 

30mA max. mod.F01 

15mA max. mod.G00 

35mA max. 

Output: 

LIGHT or DARK; PNP or NPN (short-circuit protection) 

Output current: 

100 mA max. 

Output saturation voltage: 

1.5 V max. 

1.5 V max. 

Response time: 

250 us max. 

Switching frequency: 

2KHz max. 

Indicators: 

OUTPUT LED (YELLOW); STABILITY LED (GREEN) mod. B01/F01 

POWER ON LED (GREEN) mod. G00 

Setting: 

Trimmer (250°) 

6 turns screw 

Detection Mode Setting: 

LIGHT/DARK Trimmer 

Operating temperature: 

-10 … +55 °C (-10 … +50 °C UL Listed) 

Storage temperature: 

-25 … +70 °C no freezing or condesation 

Operating distance (minimum): 

0.3...10 m on R2 

0...30 m 

20…250mm 

(white paper 200x200 mm) 

Insulating strength: 

500 Vac 1 min., between electronics and housing 

Insulating resistance: 

>20 M

 500 Vdc, between electronics and housing 

Adjustable setting range: 

--- 

40…300 mm 

Difference on White 90% / Gray 18%: 

--- 

10%  

Minimum sensing object (typical): 

Ø6 mm @ 3 m 

(opaque) 

Ø6 mm @ 3 m (opaque) 

Ø0.2 mm @ 170 mm 

(copper wire) 

Emission type: 

Red Laser diode(Emission wavelength: 650nm) 

IEC/JIS CLASS1 

*

 ; Maximum output: 7mW 

Ambient light rejection: 

according to EN 60947-5-2 

Vibration: 

0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) 

Shock resistance: 

11 ms (30 G) 6 shock for every axis (EN60068-2-27) 

Housing: 

Body PBT / indicators cover PC 

Lenses: 

PMMA 

Protection class: 

IP67 

Connections: 

2 m cable 

 3.5 mm / M8-4 pole connector 

**

 

Weight: 

50 g. max. cable versions / 10 g. connector versions 

This product complies with FDA regulations 21CFR 1040.10 and 1040.11 based on Notice No.50. 

** 

Use a UL Listed (CYJV/CYJV7) mating connector/cord assembly when using connector type as UL/c-UL listed products.

 

SETTING 

Alignment

 

S3Z…B01 

Position the sensor and reflector on opposite sides. 
Turn the sensitivity trimmer to maximum. Find the points where 
the yellow LED (OUT) is switched ON and OFF in both vertical 

Alignment

 

S3Z…M01 

Referring to the table below, adjust the distance of the photoelectric sensor 
when necessary. The table explains the status of operation LED when the 
operation mode is set to light ON.

and horizontal positions, and fix the sensor in the centre 
between these points. Optimum operation is obtained when the 
green LED is ON. 
If necessary, reduce sensitivity using the trimmer, in order to 
detect very small or transparent targets. In order to improve 
alignment, repeat the procedure detailed above whilst 
progressively reducing the sensitivity. 
 

Alignment S3Z…F01/G00 

Position the sensors on opposite sides. 
Find the points where the yellow LED (OUT) is switched ON and 
OFF in both vertical and horizontal positions, and fix the sensor 
in the centre between these points.  
Optimum operation is obtained when the green LED is ON.

 

Step 

Distance 

control 

Adjusting procedure 

 

Install a photoelectric sensor and the sensing 
object. Turn the control counter-clockwise until the 
operation LED turns OFF. Then turn clockwise until 
the operation LED turns ON (point A). 

 

Remove the sensing object, then the operation LED 
turns OFF. Turn clockwise until the operation LED 
turns ON, the background is detected (point B). 

 

Set the middle point between point A and B as 
point C. 

 

DIMENSIONS 

 

SAFETY PRECAUTIONS 

CAUTION

 - use of controls or adjustments or performance of procedures 

other than those specified in this mannual may result in hazardous radiation 
exposure. 

ATTENTION

 

- L'utilisation des commandes, ainsi que les modifications de 

réglages ou de procédures d’exécution autres que ceux specifiés dans ce 
mode d'emploi peut entraîner une exposition à des rayonnements dangereux. 

This product emits a visible laser beam. Do not stare into the beam directly. 
Furthermore, do not look the laser which is reflected at a mirror-like object. 
About safety standards of laser product, IEC60825-1 ”Safety of laser products” 
has been stipulated by the IEC (International Electortechnical Commission). 
This product is classified as “CLASS1 product” according to IEC60825-1 
(2007). Use a UL Listed (CYJV/CYJV7) mating connector/cord assembly when 
using connector type as UL/c-UL listed products. 

CAUTION

 - This Product complies with 

21 CFR 1040.10 and 1040.11 except for 
deviations pursuant to Laser Notice No. 
50, dated June 24, 2007, issued by 
CDRH (Center of Devices and 
Radiological Health) under FDA (Food 
and Drug Administration). 

ATTENTION

 - Ce produit est conforme 

aux normes 21 CFR 1040.10 et 1040.11, 
à l'exception des dérogations relatives au document « Laser Notice No.50 » du 
24 juin 2007 émis par CDRH (Center of Devices and Radiological Health) de la 
FDA (Food and Drug Administration).  

Labels: Following “Warning label” and “Certification/ Identification label” are 
affixed on this product according to IEC 60825-1 and laser regulation of FDA. 
When this product will be incorporated into final device system which is 
exported to the USA, make sure that Certification/Identification label is affixed. 

The sensors are NOT safety devices, and so MUST NOT be used 

in the safety control of the machines where installed. 

 

Datalogic S.r.l. 

Via S. Vitalino 13 - 40012 Calderara di Reno - Italy 
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com

 

 

Helpful links at www.datalogic.com: 

Contact Us,

 

Terms and Conditions,

 

Support

 

The warranty period for this product is 36 months. See General Terms and 
Conditions of Sales for further details. 

 

Under current Italian and European laws, Datalogic is not obliged to take 
care of product disposal at the end of its life. Datalogic recommends 
disposing of the product in compliance with local laws or contacting 
authorised waste collection centres. 

 

© 2012 - 2017 Datalogic S.p.A. and/or its affiliates 

 ALL RIGHTS RESERVED. 

 

Without limiting the rights under copyright, no part of this documentation may 
be reproduced, stored in or introduced into a retrieval system, or transmitted in 
any form or by any means, or for any purpose, without the express written 
permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic 
logo are registered trademarks of Datalogic S.p.A. in many countries, including the 
U.S.A. and the E.U. All other trademarks and brands are property of their 
respective owners. Datalogic reserves the right to make modifications and 
improvements without prior notification. 
 