background image

LED and Beeper Indications

34

QuickScan™ QM2400

a

Except when in sleep mode or when a Good Read LED Duration other than 
00 is selected

Programming Mode

 - The following indications ONLY occur when 

the reader is in Programming Mode.

Green Spot

a

 

flashes 
momentar-
ily

Upon successful 
read of a label, 
the software 
shall turn the 
green spot on for 
the time specified 
by the configured 
value.

N/A

N/A

Indication

Description

LED

Beeper

Label Program-
ming Mode Entry

A valid program-
ming label has 
been scanned.

LED blinks 

continu-

ously

Reader sounds 
four low fre-
quency beeps.

Label Program-
ming Mode Rejec-
tion of Label

A label has been 
rejected.

N/A

Reader sounds 
three times at 
lowest fre-
quency and 
current vol-
ume.

Label Program-
ming Mode 
Acceptance of 
Partial Label

In cases where 
multiple labels 
must be scanned 
to program one 
feature, this indi-
cation acknowl-
edges each 
portion as it is 
successfully 
scanned.

N/A

Reader sounds 
one short beep 
at highest fre-
quency and 
current vol-
ume.

Label Program-
ming Mode 
Acceptance of 
Programming

Configuration 
option(s) have 
been successfully 
programmed via 
labels and the 
reader has exited 
Programming 
Mode.

N/A

Reader sounds 
one high fre-
quency beep 
and 4 low fre-
quency beeps 
followed by 
reset beeps.

Label Program-
ming Mode Can-
cel Item Entry

Cancel label has 
been scanned.

N/A

Reader sounds 
two times at 
low frequency 
and current 
volume.

Indication

Description

LED

Beeper

Summary of Contents for QuickScan QM2400

Page 1: ...QuickScan QM2400 General Purpose Handheld Area Imager Bar Code Reader with Datalogic s STAR Cordless System Quick Reference Guide...

Page 2: ...you can acquire printed versions by contacting your Datalogic repre sentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate med...

Page 3: ...M2400 10 Linking the Reader 11 Link Datalogic RF Devices to Base 11 Power Off 11 Programming 11 Using Programming Bar Codes 12 Configure Other Settings 12 Resetting Standard Product Defaults 12 Select...

Page 4: ...ii QuickScan QM2400 Warranty Claims Process 38 Warranty Exclusions 39 No Assignment 40 Risk of Loss 40 Ergonomic Recommendations 41 Cleaning 42 Support Through the Website 43...

Page 5: ...c or the third party from whom Datalogic has obtained a license right This Agreement does not grant to End User any intellectual property rights As used in this Agree ment the term purchase or its equ...

Page 6: ...R FEE PAID BY END USER FOR THE DATALOGIC PRODUCT UNDER NO CIRCUM STANCES SHALL DATALOGIC OR ITS LICENSORS BE LIABLE TO END USER OR ANY THIRD PARTY FOR LOST PROFITS LOST DATA INTERRUPTION OF BUSINESS O...

Page 7: ...which Open Source Software packages have source code provided or available 11 Notices All notices required or authorized under this Agreement shall be given in writing and shall be effective when rece...

Page 8: ...e SIAC Rules for the time being in force which rules are deemed to be incorporated by reference in this clause The seat of the arbitration shall be Singapore The number of arbitrators will be three wi...

Page 9: ...The QuickScan QM2400 is a powerful omni directional reader so the orientation of the symbol is not important Datalogic s exclusive patented Green Spot for good read feedback helps to improve productiv...

Page 10: ...ion see page 11 4 Select the Interface Type see page 13 5 Configure the Reader starting on page 12 optional depends on settings needed Locking the Reader to the Base The Base Station provides a lockin...

Page 11: ...by pushing up the lever as far as it will go Figure 2 Lever in locked position NOTE It is good practice to put the scanner in the locked condition at the end of the working shift or when not in use fo...

Page 12: ...the rubber Cable Stopper from the bottom of the Base Station 2 Securely plug the Power Cable and Interface I F Cable connectors into their respective ports in the underside of the Base Station NOTE T...

Page 13: ...ify before connection that the reader s cable type is compatible with your host equipment Most connections plug directly into the host device as shown in Figure 4 Keyboard Wedge interface cables have...

Page 14: ...nection Plug the AC Adapter into an approved AC wall socket with the cable facing downwards as shown in Figure 3 to prevent undue strain on the socket System and Network Layouts Stand Alone Layout Fig...

Page 15: ...gure 6 QuickScan Base LEDs Table 1 Radio Base LEDs LED STATUS Power on Data Yellow On Base is powered Yellow Blinking Base receives data and commands from the Host or the Reader Charging Red On the Ba...

Page 16: ...e LEDs on the base shown in Table 1 on page 7 will indi cate the status of the battery Alternatively the battery can be charged by connecting the reader directly to a host through the micro USB connec...

Page 17: ...eader To mount the new battery pack reverse the process 1 Insert the top of the new pack inside the reader s han dle 2 Rotate the battery pack downward while pressing the bottom side of the battery pa...

Page 18: ...tem will be smaller when the reader is closer to the bar code and larger when it is farther from the code Symbolo gies with smaller bars or elements mil size should be read closer to the unit Symbolog...

Page 19: ...ar code below to shut off power to the handheld until the next trigger pull PowerOff Programming The reader is factory configured with a set of standard default features After scanning the interface b...

Page 20: ...tion Configure Other Settings Additional programming bar codes are available in the PRG to allow for customizing programming features If your installa tion requires different programming than the stan...

Page 21: ...onal information associated with each interface proceed to the corresponding chapter in the Quick Scan Q2400 PRG Configuring the Interface Scan the programming bar code which selects the appropriate i...

Page 22: ...S232 STD RS 232 Wincor Nixdorf Select RS232 WN RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS USB COM to simulate RS 232 standard interface Select USB COM STDa USB OEM USB OEM can be used fo...

Page 23: ...AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD AT NK AT PS 2 25 286...

Page 24: ...D XT Keyboard Wedge for IBM Terminal 3153 Select KBD IBM 3153 Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard Select KBD IBM M Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 3...

Page 25: ...ithout alternate key encoding AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Std Key Encoding Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 28...

Page 26: ...ONLY the following Country Modes U S Belgium Britain France Germany Italy Spain Sweden COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium Country Mode Britain Country Mode...

Page 27: ...rence Guide 19 COUNTRY MODE continued Country Mode Czech Republic Country Mode Denmark Country Mode France Country Mode Germany Country Mode Hungary Country Mode Italy Supports only the interfaces lis...

Page 28: ...Scan QM2400 COUNTRY MODE continued Country Mode Japanese 106 key Country Mode Norway Country Mode Poland Country Mode Portugal Country Mode Romania Country Mode Spain Supports only the interfaces list...

Page 29: ...e Base Interface Type Quick Reference Guide 21 COUNTRY MODE continued Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Supports only the interfaces listed in the Country Mode feature...

Page 30: ...the format in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding keyboard is selected ENTER EXIT PROGRAMMING MODE Caps...

Page 31: ...option specifies the setting of the Numbers Lock Num lock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard ENTER EXIT PRO...

Page 32: ...ll briefly switch off during the acquisition time and if no code is decoded will switch on again before the next acquisition The illuminator will remain on until the symbol is decoded As you read code...

Page 33: ...led by a good read green spot Use the bar codes below to specify the duration of the good read pointer beam after a good read ENTER EXIT PROGRAMMING MODE Green Spot Duration Disable Green Spot is Off...

Page 34: ...pulled again to transition to another state Double Read Timeout1 prevents undesired multiple reads while in this mode Flashing The reader flashes1 on and off regardless of the trigger status Always On...

Page 35: ...uick Reference Guide 27 SCAN MODE ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode Always On Scan Mode...

Page 36: ...Trigger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically disabled Multiple Labels in a Volume Enables disables the ability of scanner to decode multiple labels i...

Page 37: ...tely 200 g reader 230 g base charger Electrical Characteristics Battery Type Li Ion battery pack Typical charge time for full charge from full discharge 6 hours with Host Power through the micro USB c...

Page 38: ...Field Typical a a 13 mils DOF based on EAN All other 1D codes are Code 39 All labels grade A typical environmental light 20 C label inclination 10 Symbology Code 39 5mil 0 2 5 9 0 5 15cm 10mil 0 8 7...

Page 39: ...Aztec Datamatrix Inverse Datamatrix Data matrix is configurable for the following parameters Normal or Inverted Square or Rectangular Style Data length 1 3600 char acters Maxicode QR Codes QR Micro QR...

Page 40: ...Scanner withstands 18 drops from 1 5 meters 4 9 feet to concrete Ambient Light Immunity Up to 100 000 Lux Contaminants Spray rain Dust particulates IEC 529 IP42 scanner only ESD Level 16 KV a It is ac...

Page 41: ...t highest fre quency and vol ume upon power up Good Read Beep A label has been successfully scanned by the reader LEDbehaviorfor this indication is configurable via the feature Good Read When to Indi...

Page 42: ...abel A label has been rejected N A Reader sounds three times at lowest fre quency and current vol ume Label Program ming Mode Acceptance of Partial Label In cases where multiple labels must be scanned...

Page 43: ...1 Configuration Contact Helpdesk for assistance 2 Interface PCB 6 Digital PCB 12 Imager Indication LEDS Power up Complete Yellow LED on Reader Disabled by the HOST or the communication with HOST is n...

Page 44: ...scrap all parts removed from the repaired prod uct The warranty period shall extend from the date of ship ment from Datalogic for the duration published by Datalogic for the product at the time of pu...

Page 45: ...e personnel or its authorized represen tatives ii any claimed defect failure or damage which Data logic determines was caused by faulty operations improper use abuse misuse wear and tear negli gence i...

Page 46: ...FROM DELAYS IN THE REPLACEMENT OR REPAIR OF PRODUCTS UNDER THE ABOVE THE REMEDY SET FORTH IN THIS WARRANTY STATE MENT IS THE CUSTOMER S SOLE AND EXCLUSIVE REMEDY FOR WARRANTY CLAIMS UNDER NO CIRCUMST...

Page 47: ...at correct heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work pro...

Page 48: ...eded to ensure a good con nection Be sure to unplug the product from electrical outlet before cleaning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft clot...

Page 49: ...eneral Duty Handheld Scanners category link From this page you can select your product model from the dropdown list which gives you access to Downloads including Data Sheets Manuals Software Utili tie...

Page 50: ...Support Through the Website 42 QuickScan QM2400 NOTES...

Page 51: ......

Page 52: ...Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic USA Inc 959 Terry Street Eugene OR 97402 USA Telephone 541 68...