QUICKSCAN
®
MOBILE
126
4.2.3
Overflow
This parameter generates a white space before the first bar and after the last bar of
the code. The selections are as follows:
narrow
= space 10 times the minimum output pulse.
medium = space 20 times the minimum output pulse.
wide
= space 30 times the minimum output pulse.
4.2.4
Output and Idle Levels
The following state diagrams describe the different output and idle level combinations
for Pen emulation:
bar
space
white
black
barcode output
idle
OUTPUT: Normal
IDLE: Normal
bar
space
white
black
barcode output
idle
OUTPUT: Normal
IDLE: Inverted
bar
space
white
black
barcode output
idle
IDLE: Normal
OUTPUT: Inverted
bar
space
white
black
barcode output
idle
IDLE: Inverted
OUTPUT: Inverted
Output and Idle Levels