Technical Specifications
18
QUICKSCAN™ QD2200
TECHNICAL SPECIFICATIONS
The following table contains Physical and Performance
Characteristics, User Environment and Regulatory infor
-
mation.
PHYSICAL CHARACTERISTICS
Color
Black
Dimensions
Height 15.6 cm (6.1”)
Length 10.7 cm (4.2”)
Width 6.7 cm (2.6”)
Weight (without
cable)
QD2200 approx. 123 g (4.34 oz.)
ELECTRICAL CHARACTERISTICS
Power Supply
QD4220: 5VDC ± 5%
Consumption
Operating (Typical): <500mA @ 5V
Standby/Idle (Typical): <50mA @5V
Max. Scan Rate
400 reads/sec
Reading Indicators Top illumination, Good Read Spot, Beep
ENVIRONMENTAL CHARACTERISTICS
Operating
Temperature
0 °C to + 50 °C (+32° F to +122 °F)
Storage Tempera
-
ture
-40 °C to + 70 °C (-40 ° F to +158 °F)
Humidity
95% non condensing
Drop Resistance
IEC 68-2-32 Tested
1.5 m (5 ft)
ESD Protection
16 KV
Protection Class
IP42
Ambient Light
120000 lux
Cable Length
Refer to
OPTICAL CHARACTERISTICS
Tilt Tolerance
a
a. Based on ISO 15423 specifications.
± 45°
Pitch Tolerance
a
± 65°
Skew Tolerance
a
± 65°
Field of View
a
HORIZONTAL 56° +/- 2°
PCS
(Datalogic Test
Chart)
minimum 15%