Enter/Exit Programming Mode
268
QuickScan™ I QD21X1 / QM21X1 / QBT21X1
Source Radio Address Delimiter Character
This option specifies the delimiter character to be placed between the label
data and radio address when address stamping is enabled.
NOTE
Set Source Radio Address Delimiter Character
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
left followed by the digits from the Alphanumeric char-
acters in
representing your desired char-
acter(s). End by scanning the ENTER/EXIT bar code
again.
Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
This feature only applies if
"Source Radio Address Transmission"
page 267 is enabled.
Link Timeout
This feature specifies the wait time in one-second ticks for response from the
remote. The selectable timeout range is 01 to 40 (01-0x28) seconds in one
second increments.
Set Link Timeout
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
left followed by the digits from the Alphanumeric char-
acters in
representing your desired char-
acter(s). End by scanning the ENTER/EXIT bar code
again.
Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
00 = No Delimiter Character
DEFAULT
02 Link Timeout value is 2 seconds
Summary of Contents for QBT2101-BK-BTK+
Page 30: ...20 QuickScan I QD21X1 QM21X1 QBT21X1...
Page 66: ...Enter Exit Programming Mode USB Keyboard Speed 56 QuickScan I QD21X1 QM21X1 QBT21X1 NOTES...
Page 264: ...Symbologies 254 QuickScan I QD21X1 QM21X1 QBT21X1 NOTES...
Page 342: ...332 QuickScan I QD21X1 QM21X1 QBT21X1 Code 32 Codabar Code 93 Code 11...
Page 344: ...334 QuickScan I QD21X1 QM21X1 QBT21X1 NOTES...
Page 346: ...336 QuickScan I QD21X1 QM21X1 QBT21X1 5 6 7 8 9...
Page 347: ...Product Reference Guide 337 A B C D E F...